Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation · MERC

Operation of a 2-Stage Bioelectrochemical System for Groundwater Denitrification

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

KI-angereichert· 78 %Substrat ·synthetic mixture

Zusammenfassung

Nitrate groundwater contamination is an issue of global concern that has not been satisfactorily and efficiently addressed, yet. In this study, a 2-stage, sequential bioelectrochemical system (BES) was run to perform autotrophic denitrification of synthetic groundwater. The system was run at a 75.6 mgNO3−-N L−1NCC d−1 nitrate loading rate, achieving almost complete removal of nitrate (>93%) and Total Nitrogen (TN) (>93%). After treatment in the first stage reactor values of effluent nitrate compatible with the EU and USA limits for drinking water (<11.3 and 10 mgNO3−-N L−1, respectively) were achieved. Nitrite and nitrous oxide were observed in the first stage’s effluent, and were then successfully removed in the second stage. The observed nitrate removal rate was 73.4 ± 1.3 gNO3−-N m−3NCC d−1, while the total nitrogen removal rate was 73.1 ± 1.2 gN m−3NCC d−1. Specific energy consumptions of the system were 0.80 ± 0.00 kWh m⁻³, 18.80 ± 0.94 kWh kgNO3−-N−1 and 18.88 ± 0.95 kWh kgN−1. Combination of two denitrifying BES in series herein described proved to be effective.

KI-Zusammenfassung

78 % Konfidenz

This study demonstrates a 2-stage bioelectrochemical system (BES) for autotrophic denitrification of synthetic groundwater at 75.6 mgNO3−-N L−1NCC d−1 loading rate. The first stage achieved 88% nitrate removal but accumulated nitrite (1.5 mgNO2−-N L−1) and unexpectedly high N2O (concentration not explicitly stated but dominant non-nitrate TN form). The second stage polished these intermediates to <0.1 mg/L each, achieving >93% overall removal and drinking water compliance (QR=0.2). Energy consumption was 18.8 kWh/kgNO3−-N, competitive with reverse osmosis and electrodialysis. The key finding is that intermediate N-form accumulation at high loads requires staged treatment, not just potential optimization.

Zentrale Erkenntnisse

  • Schwellenwert N2O became the dominant intermediate nitrogen form in BES-1 effluent (concentration higher than nitrite throughout), contrary to the authors' prior single-stage experience, indicating that high nitrate loading (75.6 vs. prior 67.0 mgNO3−-N L−1NCC d−1) shifts the denitrification bottleneck from nitrite to N2O reduction.

    Was heißt das. Operators scaling up single-stage BES must expect N2O accumulation at higher loads and plan for a second polishing stage; N2O reduction kinetics, not just nitrate-to-nitrite conversion, becomes the rate-limiting step.

  • Zielkonflikt BES-2 achieved 90% coulombic efficiency versus 57% for BES-1, despite lower current density (14 vs. 37.7 A m−3NCC), because it operated as a polishing step on low-concentration intermediates rather than bulk nitrate reduction.

    Was heißt das. Second-stage BES design should prioritize electrode surface area and biofilm development for intermediate reduction rather than bulk current capacity; efficiency improves when substrate concentration is low.

  • Zielkonflikt The sequential system's SECN (18.80 kWh/kgNO3−-N) was higher than the authors' prior single-stage work (3.17 kWh/kgNO3−-N) despite similar potentials (−0.303 V vs. SHE), because the higher loading rate (75.6 vs. prior unspecified) and presence of two reactors increased total power demand relative to nitrate removed.

    Was heißt das. Energy efficiency in multi-stage BES is not additive; the second stage consumes power for low-concentration polishing, so operators must balance removal completeness against energy cost per kg N removed.

  • Mechanismus BES-2 inlet pH was 8.6 ± 0.5 (far from the reported optimal 7.5), yet it still achieved near-complete nitrite and N2O removal (0.1 mg/L each), contradicting the claim that pH is a major player in biocathodic denitrification.

    Was heißt das. pH control may be less critical for intermediate N-form reduction than for initial nitrate reduction; operators can relax pH buffering in polishing stages, reducing operational complexity.

  • Mechanismus The system maintained QR = 0.2 ± 0.1 (well below the limit of 1.0) despite inlet pH 8.6 and high loading, suggesting that the microbial community adapted to the elevated pH and high intermediate concentrations, or that the second stage's lower load allowed complete conversion regardless of inlet conditions.

    Was heißt das. Two-stage design provides robustness to pH and load variability; the second stage acts as a buffer that absorbs upstream fluctuations in intermediate accumulation.

Widersprüche2

Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.

  • Innerhalb der Publikation pH claimed as major player in denitrification, yet BES-2 succeeds at non-optimal pH

    Eine Seite

    pH reported as optimal around 7.5 for biocathodic denitrification [38,55]

    “Even though pH has been claimed as a major player in the biocathodic denitrification process, with optimal values around 7.5 [38,55]”
    Andere Seite

    BES-2 inlet pH 8.6 ± 0.5 achieved nearly complete nitrite and N2O removal (0.1 mg/L each)

    “in this study no evidence of accumulation of intermediate N-forms due to pH was recorded: BES-2, whose influent pH was far from neutrality (8.6 ± 0.5)... succeeded in achieving almost a complete removal of nitrite and nitrous oxide”

    Einordnung der Autoren. Authors acknowledge the contradiction but do not fully resolve it; suggest that pH may be less critical for intermediate reduction than for initial nitrate reduction, or that the second stage's lower load compensates for suboptimal pH.

  • Innerhalb der Publikation N2O accumulation in this work contradicts prior single-stage experience

    Eine Seite

    Prior single-stage BES work showed nitrite as dominant intermediate, not N2O

    “whose presence was not relevant in our previous experience”
    Andere Seite

    Current work: 'the majority of non-nitrate TN was originated from nitrous oxide, which concentration was far higher than that of nitrite during the whole experiment, and whose presence was not relevant in our previous experience'

    “the majority of non-nitrate TN was originated from nitrous oxide, which concentration was far higher than that of nitrite during the whole experiment”

    Einordnung der Autoren. Authors attribute this to higher nitrate loading rate (75.6 vs. 67.0 mgNO3−-N L−1NCC d−1 in prior work), suggesting a load-dependent shift in the rate-limiting step of denitrification. The mechanism is not fully investigated.

Ansatzpunkte6

Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.

  • Hoch N2O accumulation mechanism and threshold loading rate not characterized. Paper shows N2O dominates at 75.6 mgNO3−-N L−1NCC d−1 but does not test intermediate loading rates (e.g., 67–75 mgNO3−-N L−1NCC d−1) to identify the transition point.

    Authors state 'whose presence was not relevant in our previous experience' at lower load, indicating a threshold exists, but it is not mapped. This is critical for predicting when single-stage BES will fail.

    Versuch. Vary nitrate loading rate from 50 to 100 mgNO3−-N L−1NCC d−1 in single-stage BES at −0.303 V vs. SHE; measure N2O, NO2−, and NO3− in effluent to identify the loading rate at which N2O becomes dominant.

  • Hoch Cathode potential optimization for intermediate N-form reduction not explored. Both stages operated at identical potential (−0.303 V vs. SHE), yet literature (Pous et al. [65]) suggests nitrate and nitrite reduction occur at different potentials.

    Authors note in Discussion: 'Pous et al. [65] reported that nitrate and nitrite reduction happened at different potentials; the operation of the sequential system with different set potentials in the different steps may constitute an evolution of the BES-based denitrification described in this study.' This is explicitly identified as a gap.

    Versuch. Test BES-2 at potentials ranging from −0.2 to −0.5 V vs. SHE while maintaining BES-1 at −0.303 V; measure N2O and NO2− removal rates and coulombic efficiency to identify optimal potential for polishing stage.

  • Mittel HRT and current density trade-off in second stage not optimized. BES-2 HRT is 4.16 h with current density 14 A/m³NCC; paper does not test whether shorter HRT or higher current density would improve N2O/NO2− removal without increasing energy cost.

    BES-2 operates at low load (16.3 gNO3−-N/m³NCC d−1 removal vs. 117.3 in BES-1), suggesting it is oversized. Authors note 'the system may work at a higher nitrate load to fully profit from the presence of BES-2,' implying HRT could be reduced.

    Versuch. Reduce BES-2 HRT from 4.16 h to 2–3 h by increasing flow rate; measure N2O and NO2− removal efficiency and energy consumption to identify minimum HRT for complete polishing.

  • Mittel Microbial community composition and adaptation to high N2O loads not characterized. Paper does not identify which organisms reduce N2O or why they accumulate it at high loading.

    Authors mention 'Proteobacteria have been reported as abundant or dominant' and cite Vilar-Sanz et al. [36] showing monospecific biofilms cannot complete denitrification, but do not characterize their own biofilm or explain N2O accumulation mechanism.

    Versuch. Perform 16S rRNA gene sequencing and metatranscriptomics on BES-1 and BES-2 biofilms at 75.6 mgNO3−-N L−1NCC d−1 loading; correlate community composition with N2O and NO2− accumulation patterns.

  • Mittel Dissolved oxygen and anoxic conditions in cathodic chamber not monitored. Paper does not report DO levels, which could compete with nitrate as electron acceptor and explain intermediate accumulation.

    Autotrophic denitrification requires anoxia, but paper does not confirm DO was <0.5 mg/L or measure it during operation. High DO could suppress N2O reductase expression.

    Versuch. Monitor dissolved oxygen in BES-1 and BES-2 cathodic chambers continuously; correlate DO spikes with N2O and NO2− accumulation to test whether oxygen ingress is a contributor.

  • Niedrig Catholyte pH buffering capacity and long-term stability not tested. Anodic solution pH dropped to 5 every two weeks, requiring replacement; no data on whether this cycling affects biofilm stability or denitrification kinetics.

    Paper states 'Anodic solution was continuously recirculated in closed-loop mode, and substituted when its pH reached a value of 5 (usually every two weeks)' but does not measure biofilm response or test alternative buffering strategies.

    Versuch. Increase anodic buffer capacity (e.g., higher PBS concentration or alternative buffer) and measure whether pH cycling frequency decreases and whether denitrification performance improves.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 49 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

19 von 49 extrahierten Zeilen modellierbar

  • 10 nicht kanonisiert (kein kanonischer Slug)
  • 17 kein SI-Wert
  • 3 widerspricht anderen Publikationen
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Hydraulic retention time5,4h95 %
calculation from volume and flow rate
"The HRT of BES-1 was 5.4 h" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Reactor Volume640mL95 %
extrahiert
"while BES-2 anodic chamber was filled with granular graphite obtaining a final fre…" · condition_hint=design parameter, electrode_material=granular graphiteModellierbar
Electrical Conductivity4.150µS cm⁻¹95 %
conductivity probe
"The conductivity of the cathodic influent was 4152 ± 567 µS cm−1" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Nitrate loading rate75,6mgNO3−-N L−1NCC d⁻¹95 %
continuous operation monitoring
"The system was run at a 75.6 mgNO3−-N L−1NCC d−1 nitrate loading rate" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Specific Energy Consumption0,64kWh m⁻³95 %
power integration over time
"Table 2. Specific energy consumption calculated for each stage and for the sequen…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: widerspricht anderen Publikationen
Specific Energy Consumption0,8kWh m⁻³95 %
power integration over time
"Specific energy consumptions of the system were 0.80 ± 0.00 kWh m−3" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: widerspricht anderen Publikationen
Nitrogen Removal43,6gN m−3NCC d⁻¹95 %
mass balance calculation
"and 43.6 ± 7.9 gN m−3NCC d−1, respectively" · T=23°C, pH(an)=8.6, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Alkalinity1,6g L⁻¹95 %
preparation of synthetic medium
"Synthetic groundwater with micronutrients (0.326 g L−1 KNO3, 1.600 g L−1 NaHCO3" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Reactor Volume760mL95 %
extrahiert
"A folded stainless steel mesh (40 × 20 cm) was used as electrode in the anodic c…" · condition_hint=design parameter, electrode_material=stainless steel meshModellierbar
Influent nitrate concentration45,2mgNO3−-N L⁻¹95 %
preparation of synthetic medium
"Synthetic groundwater with micronutrients (0.326 g L−1 KNO3" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: nicht kanonisiert (kein kanonischer Slug)
Nitrate Removal Efficiency117gNO3−-N m−3NCC d⁻¹95 %
mass balance calculation
"The nitrate removal rate of the sequential system during the experimentation was…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Nitrogen Removal95,7gN m−3NCC d⁻¹95 %
mass balance calculation
"Contrary, BES-2 was active mainly in the removal of nitrite and nitrous oxide; t…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Specific Energy Consumption18,9kWh kgN⁻¹95 %
power integration over time
"and 18.88 ± 0.95 kWh kgN−1" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Current Density (Basis Unresolved)37,7A m−3NCC95 %
potentiostat monitoring
"BES-1 reached higher values than BES-2 (37.7 ± 0.8 A m−3NCC" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Nitrate Removal Efficiency73,4gNO3−-N m−3NCC d⁻¹95 %
mass balance calculation
"The observed nitrate removal rate was 73.4 ± 1.3 gNO3−-N m−3NCC d−1" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Nitrate Removal Efficiency16,3gNO3−-N m−3NCC d⁻¹95 %
mass balance calculation
"and 16.3 ± 5.9 gNO3−-N m−3NCC d−1" · T=23°C, pH(an)=8.6, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Hydraulic retention time4,16h95 %
calculation from volume and flow rate
"while that of BES-2 was 4.16 h" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Reactor Volume675mL95 %
extrahiert
"The cathodic chambers were both filled with granular graphite (model 00514, diame…" · condition_hint=design parameter, electrode_material=granular graphiteModellierbar
Specific Energy Consumption20,2kWh gN⁻¹95 %
power integration over time
"Table 2. Specific energy consumption calculated for each stage and for the sequen…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Hydraulic retention time9,56h95 %
calculation from volume and flow rate
"The hydraulic retention time (HRT) of the entire system was 9.56 h" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Power Density (Basis Unresolved)26,4W m−3NCC95 %
potentiostat monitoring
"and 26.4 ± 2.3 W m−3NCC respectively" · T=23°C, pH(an)=8.6, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
Maximum Operating Temperature23°C95 %
ambient measurement
"The experiments were performed at ambient temperature (23 ◦C)" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Reactor Volume520mL95 %
extrahiert
"and 520 mL (NCC) for BES-2" · condition_hint=design parameter, electrode_material=granular graphiteModellierbar
Flow Rate2L d⁻¹95 %
peristaltic pump setting
"The system was run at the maximum NO3−-N concentration applied in our previous s…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateModellierbar
Power Density (Basis Unresolved)26,4W m−3NCC95 %
potentiostat monitoring
"higher power demands were recorded by BES-1 rather than by BES-2 (26.4 ± 2.3 W m…" · T=23°C, pH(an)=7, substrate=synthetic_groundwater_with_nitrate, steady_stateAusgeschlossen: kein SI-Wert
25 von 49 angezeigt

Methodik

Welches System und wie es betrieben wurde

Methodik

Methodology

Two dual-chamber BES reactors (BES-1 and BES-2) with granular graphite cathodes (675 mL and 520 mL net cathodic compartment, respectively) and abiotic anodes were operated in series at −0.303 V vs. SHE (controlled by potentiostat). Synthetic groundwater (45.2 mgNO3−-N L−1) was fed at 2 L/d (75.6 mgNO3−-N L−1NCC d−1 loading, 9.56 h total HRT). Effluent was sampled daily for NO3−-N, NO2−-N, and TN (spectrophotometry); N2O-N was calculated as TN minus other N-forms. Current and power were logged every minute. Coulombic efficiency and specific energy consumption were calculated per standard equations.

Systemkonfiguration

FeldWert
reactor typeBES
chamber config2-chamber

Leistungskennzahlen

FeldWert
citation count15

Betriebsbedingungen

5 Läufe extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-25bcf6039713040f238.6—synthetic_groundwater_with_nitrate——steady_state—-0.303—
v2-4b19a3f77a5a345d238.6—synthetic_groundwater_with_nitrate45.2—steady_state—-0.303—
v2-6b2b8d57bbbf1fb6237—phosphate_buffer——steady_state—-0.303—
v2-ed0f77abe42175b1237—synthetic_groundwater_with_nitrate45.2—steady_state—-0.303—
v2-f586e9af22985397——————————

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Parametervollständigkeit

13 %

Anteil der erwarteten Parameter, die extrahiert wurden

Datenvollständigkeit

40 %

Gesamtabdeckung der Extraktion über alle Felder

KI-Konfidenz

78 %

Vom Modell selbst angegebene Konfidenz

Mittlere Parameterkonfidenz

93 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.

MERC
System
90,0Prozent
Bestes Ergebnis · Coulomb-Effizienz
bester von 3
49
Extrahierte Werte
2019
Jahr

Schlagwörter

  • Nitrate
  • Denitrification
  • Effluent
  • Nitrite
  • Denitrifying bacteria
  • Nitrous oxide

Zitieren

Arianna Callegari, Silvia Bolognesi, Daniele Cecconet (2019). Operation of a 2-Stage Bioelectrochemical System for Groundwater Denitrification. Water. https://doi.org/10.3390/w11050959

Zeitschrift
Water