Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

Forschung

Publikation

The Concentration Determines Reaction Efficiency of Hetero‐Coupling of Bio‐Based Medium Chain Carboxylic Acids by Kolbe Electrolysis

01

Zusammenfassung

Was die Publikation berichtet, in ihren eigenen Worten.

Kein BESElectrosynthesisBiomass Valorization

Zusammenfassung

Mixtures of seven n‐ carboxylic acids ( n‐ CA), ranging from acetic acid to n‐ octanoic acid, that can be gained from the microbial conversion of waste biomass, were converted into liquid drop‐in fuel via Kolbe electrolysis. We demonstrate a strong, sigmoidal correlation between the total n ‐CA concentration and the Coulombic efficiency for fuel‐like liquid products (CEfuel ). Crucially, only above an apparent threshold concentration of 0.1 mol L ⁻¹ n‐ CA, Kolbe electrolysis takes place, whereas at lower concentrations the oxygen evolution reaction (OER) dominates. Optimal performance was achieved at the highest concentration tested, 1.5 mol L ⁻¹ , yielding a maximum CEfuel of 63.8 ± 1.4%, whereas for n‐ CA to 0.1 mol L ⁻¹ and 0.5 mol L ⁻¹ , the chain shortening reaction (CSR) strongly affects CEfuel . Furthermore, the study provides valuable insights into reaction selectivity, demonstrating that longer‐chain n ‐CA react preferentially compared to shorter‐chain n ‐CA, a phenomenon that is attributed to their higher hydrophobicity and hence accumulation in the hydrophobic layer formed on the electrode. Using a one‐chamber cell system at optimized concentration significantly lowered energy demand to 2.92 ± 0.04 kWhL ⁻¹ of fuel produced, representing a 40% reduction compared to similar two‐chamber setups.

02

Extrahierte Werte

Jeder aus der Publikation entnommene Wert mit seiner Quelle, damit sich jede Zahl am Text prüfen lässt.

n = 97 extrahierte Werte

Wählen Sie eine Quellenangabe, um Zitat, Seite und Konfidenz hinter einem Wert zu sehen.

0 von 97 extrahierten Zeilen modellierbar

  • 97 keine Publikation zu mikrobiellen elektrochemischen Systemen
ParameterWertEinheitKonfidenzQuelleAnmerkungenModellierbar
Prolonged electrolysis charge (threshold experiments)2,5FE100 %
extrahiert
"This finding is strongly supported by experiments with prolonged Kolbe electroly…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=2.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Stirring speed800rpm100 %
extrahiert
"The electrolysis was carried out for 0.5 FE relative to the initial n-CA concent…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Charge passed (Faraday equivalents relative to initial n-CA)0,5FE100 %
extrahiert
"The electrolysis was carried out for 0.5 FE relative to the initial n-CA concent…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Supporting electrolyte (Na2CO3) concentration0,35mol L⁻¹100 %
extrahiert
"Afterwards, 61 mL of 1 mol L-1 Na2CO3 was added to reach a final Na2CO3 concentr…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Constant applied current300mA100 %
extrahiert
"The electrolysis was carried out for 0.5 FE relative to the initial n-CA concent…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Geometric surface area of platinized titanium working and counter electrodes2cm²100 %
extrahiert
"consisting of platinized titanium WE and CE (Umicore, Schwaebisch Gmuend, German…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Yield of fuel-like liquid products (Yfuel) at 1.5 mol L−183,3 ± 16.5%100 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"leading to an increasing share of products that we could detect, finally reachin…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEfuel in the OER area (up to 0.1 mol L−1 n-CA)3%100 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"First, in the OER area, that is at low n-CA concentrations of up to 0.1 mol L-1,…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEanode (all anodic products incl. O₂) at 0.5 mol L−148,5 ± 9.1%100 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"When assuming that only 13.8 ± 2.4% of the reacted n-CA would have undergone a C…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Electricity demand per liter of fuel produced (one-chamber cell)2,92 ± 0.04kWh L⁻¹100 %
extrahiert
"In this simplified scenario, the electricity cost per liter of fuel decreases by…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEOER (oxygen evolution) at 0 mol L−1 n-CA99,5 ± 8.1%100 %
micro-gc tcd (gas phase)
"with hyperbolic decline of CEOER from 99.5 ± 8.1% at 0 mol L-1 to ~60% at 0.1 mo…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Reactor volume (one-chamber configuration)100mL100 %
extrahiert
"was performed in a 100 mL reactor (Schott AG, Mainz, Germany) in one-chamber con…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Working volume of the reactor50mL100 %
extrahiert
"was performed in a 100 mL reactor (Schott AG, Mainz, Germany) in one-chamber con…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Distance between counter electrode and working electrode18mm100 %
extrahiert
"the counter electrode (CE, 18 mm distance to WE)" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
pH of the reaction solution (adjusted before electrolysis)9 ± 0.1—100 %
extrahiert
"The pH was then adjusted to 9.0 ± 0.1 using 10 mol L-1 NaOH and 3 mol L-1 or 6 m…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Initial total n-CA concentration range studied (nine concentrations)0mol L⁻¹100 %
extrahiert
"nine different concentrations of the n-CA mixture ranging from 0.0 mol L-1 to 1.…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Current density150mA cm⁻²100 %
extrahiert
"Kolbe electrolysis of n-CA mixtures containing C2 to C8 with different initial n…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEH2 (hydrogen evolution at the cathode)80%100 %
micro-gc tcd (gas phase)
"shows a constant CEH2≥80%, independent of the initial n-CA concentration" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Apparent threshold concentration of n-CA for Kolbe electrolysis0,1mol L⁻¹100 %
extrahiert
"Crucially, only above an apparent threshold concentration of 0.1 mol L-1 n-CA, K…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Maximum Coulombic efficiency for fuel-like liquid products (CEfuel)63,8 ± 1.4%100 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"Optimal performance was achieved at the highest concentration tested, 1.5 mol L-…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Total n-CA concentration of the seven-component mixture0,5mol L⁻¹100 %
extrahiert
"The n-CA mixture resembling the extraction solution from a bioprocess was used f…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Selectivity of fuel-like liquid products toward hydrocarbons in the dimerization area80%95 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"the selectivity of fuel-like liquid products toward hydrocarbons increases to ov…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEOER in the dimerization area15%95 %
micro-gc tcd (gas phase)
"Third, in the dimerization area that is for n-CA above 0.5 mol L-1, the CEfuel i…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
CEnon-Kolbe (non-Kolbe products)5%95 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"The formation of non-Kolbe products is low and independent of concentration, as …" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
Selectivity toward hydrocarbons (S hydrocarbon) in the OER area3%95 %
gc-ms (liquid phases), micro-gc tcd (gas phase)
"In the OER area up to 0.1 mol L-1 n-CA, nearly no Kolbe products are formed (CEf…" · ph=9, cell=one-chamber, 50 mL working volume, acids=["C2","C3","C4","C5","C6","C7","C8"], charge=0.5 FEAusgeschlossen: keine Publikation zu mikrobiellen elektrochemischen Systemen
25 von 89 angezeigt

Methodik

Welches System und wie es betrieben wurde

Betriebsbedingungen

1 Lauf extrahiert
LaufT°CpHAnolytpHKatholytSubstrat[S]mg/LHRThModusR_extΩV_appVInokulum
v2-631564a2744d1853209—n-carboxylic acids C2-C8 mixture, Na2CO3 electrolyte——————

Extraktionspipeline

Rohextraktionen, Artefakte, Qualitätssignal

Extraktionsqualität

Ehrlichkeitssignal

Bemessen Sie Ihr Vertrauen in die extrahierten Inhalte an diesen Signalen – so hat die Pipeline ihre eigene Ausgabe für diese Publikation bewertet.

Mittlere Parameterkonfidenz

94 %

Durchschnittliche Konfidenz der oben angezeigten PaperParameter-Zeilen

vor dem Zitieren mit dem Quell-PDF abgleichen · Werte 0–1

03

Diagramm-Explorer

Verändern Sie die Eingaben dieser Publikation und sehen Sie, wie sich das vorhergesagte Ergebnis verschiebt.

04

Modell erkunden

Der Reaktor in 3D, mit Strömung, die sich ein- und ausschalten lässt.

05

KI-Erkenntnisse

Widersprüche, Lücken und Chancen aus dem Vergleich dieser Publikation mit dem Korpus.

06

Ähnliche Publikationen vergleichen

Die nächsten Publikationen nach System, Materialien und Organismen, mit ihren Ergebnissen nebeneinander.

07

Quell-PDF

Die Publikation, wie sie erschienen ist.

Dieser Publikation ist noch kein 3D-Modell zugeordnet. Die daraus extrahierten Werte stehen unter „Extrahierte Werte“.

1500Ampere pro Quadratmeter
Bestes Ergebnis · Stromdichte
97
Extrahierte Werte
2026
Jahr

Schlagwörter

  • Kolbe electrolysis
  • medium-chain carboxylic acids
  • oxygen evolution reaction
  • reaction selectivity
  • Coulombic efficiency
  • energy demand reduction
  • drop-in fuels
  • biofuels

Zitieren

Max Pohl, Katharina Röhring, Micjel Chávez Morejón et al. (2026). The Concentration Determines Reaction Efficiency of Hetero‐Coupling of Bio‐Based Medium Chain Carboxylic Acids by Kolbe Electrolysis. ChemSusChem. https://doi.org/10.1002/cssc.70753

Zeitschrift
ChemSusChem