An integrated bubble column reactor-microbial fuel cell (BCR-MFC) was developed for simultaneous aerobic toluene vapor biodegradation, nitrification, heterotrophic denitrification, and electricity generation. The BCR-MFC was tested under various inlet loading rates (ILRs) of toluene to the bio-cathode chamber. The maximum elimination capacity (EC max ) reached 248 g m -3 h -1 at an ILR of 456 g m -3 h -1 . Optimal performance occurred at an ILR of 306 g m -3 h -1 , yielding an EC of 208 g m -3 h -1 and a voltage output of 522 mV based on the integrated efficiency parameter (ε). The highest power density (4.8 W m -3 ) was obtained at the lowest ILR (70 ± 6 g m -3 h -1 ). At an ILR of 316 ± 30 g m -3 h -1 , NH₄ + -N decreased from 1.3 g L -1 to 0.134 g L -1 , and NOₓ - -N from 1.3 g L -1 to 0.239 g L -1 . Microbial community analysis revealed increased abundance of toluene-degrading bacteria, heterotrophic denitrifiers, and nitrifiers, including Pseudomonas, Paracoccus, Zoogloea, and Bacillus. These results highlight the BCR-MFC ability to couple efficient toluene degradation with nitrogen compound removal while producing bioelectricity, facilitated by the coexistence of essential microbial species in the bio-cathode chamber.

AI summary: matches the abstract (75% confidence) · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 3 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 3 extracted rows modelable

  • 1 not canonicalised (no canonical slug)
  • 2 no SI value
ParameterValueUnitConfidenceSourceModelable
Dominant organismPseudomonas—80%
extracted
Excluded: not canonicalised (no canonical slug)
Substratetoluene—50%
extracted
Excluded: no SI value
Maximum power density4,800mW/m²50%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

The BCR-MFC was tested under various inlet loading rates of toluene to the bio-cathode chamber.

Biological parameters

FieldValue
dominant species["Pseudomonas","Bacillus"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

13%

Fraction of expected parameters extracted

Data completeness

30%

Overall extraction coverage across fields

AI confidence

75%

Model self-reported confidence

Mean parameter confidence

60%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
4800milliwatts per square metre
Best result · Power density
3
Extracted values
2025
Year

Keywords

  • Microbial fuel cell
  • Toluene
  • Heterotroph
  • Microbial population biology
  • Nutrient
  • Electricity generation

Cite

Raoof Rabiee, Seyed Morteza Zamir, Niusha Safari et al. (2025). Bio-cathodic treatment of toluene and nutrients in an integrated bubble column-microbial fuel cell: Electricity generation and microbial community shift. Bioelectrochemistry (Amsterdam, Netherlands). https://doi.org/10.1016/j.bioelechem.2025.109148

PubMed
41138672

Open in lab for full controls, parameter editing, and template overlays.

Open in lab