Paper · MFC
Enhancing microbial adhesion and electron transfer of Shewanella oneidensis MR-1 with polyaniline-glucose-gelatin coating for bioelectrochemical applications
Summary
What the paper reports, in its own words.
Abstract
Enhancing bioelectrochemical performance through electrode modifications is critical for advancing microbial fuel cell (MFC) technology. This study investigates the effect of carbon cloth modifications using polyaniline (PANI), glucose, and gelatin on biofilm formation, charge transfer, and microbial viability. Cyclic voltammetry results of initial and 7-day performance demonstrate that PANI-glucose-gelatin-biofilm modified carbon cloth (MCC.B) exhibits highest maximum current and lowest charge transfer resistance when compared with a bare carbon cloth-biofilm system with (CC.G.B) and without (CC.B) the presence of dissolved glucose. Biofilm viability studies reveal that CC.G.B supports predominantly planktonic growth, limiting bacterial adhesion, while MCC.B achieves the highest biofilm formation (90.2 ± 0.2%) and charge storage capacity (174.9 ± 10.2 mC/cm 2 ), corresponding to an approximately 50-fold increase in CSC compared with a bare carbon cloth system (3.3 ± 0.3 mC/cm 2 ), highlighting the synergistic impact of surface modifications and microbial activity. These findings demonstrate that MCC.B facilitates extracellular electron transfer by optimizing bacterial adhesion and nutrient availability, making it a promising candidate for shortening start-up and improving early-stage bioelectrode performance, while longer-term stability remains to be established. This work provides new insights into electrode engineering strategies for maximizing microbial interaction and electrochemical performance in next-generation microbial electrochemical technologies. • Novel electrode modification strategy for microbial fuel cells was developed. • Carbon cloth was modified with polyaniline, glucose, and a protective gelatin layer. • Higher biofilm adhesion and improved cell viability were observed on modified electrodes. • Higher capacitance and lower charge transfer resistance were noted with modified carbon cloth.
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
No PDF on file yet
MESSAI holds the bibliographic record for this paper but not its PDF, so there is no text to extract values from.
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 2
Keywords
- Shewanella oneidensis
- Microbial fuel cell
- Biofilm
- Chemical engineering
- Carbon fibers
- Electrode
Cite
Kamran Ayaz, Ewa Zabłocka-Godlewska, Abdullah et al. (2026). Enhancing microbial adhesion and electron transfer of Shewanella oneidensis MR-1 with polyaniline-glucose-gelatin coating for bioelectrochemical applications. Journal of environmental chemical engineering. https://doi.org/10.1016/j.jece.2026.121546
Open in lab for full controls, parameter editing, and template overlays.
Open in lab