Research

Paper · MERC

Chromium Reduction via a Semi-Conducting Hematite Electrode: Implications for Microbial Cycling of Metals in Natural Soils

01

Summary

What the paper reports, in its own words.

AI Enhanced· 90%Substrate ·pure compound

Abstract

Semi-conducting Fe oxide minerals, such as hematite, are well known to influence the fate of contaminants and nutrients in many environmental settings and influence microbial growth under suboxic to anoxic conditions through a myriad of different processes. Recent studies of Fe oxide reduction by Fe(II) have demonstrated that reduction of Fe at one surface can result in the release of Fe(II) different one. Termed Fe(II) catalyzed recrystallization, this phenomena is attributed to conduction of additional electrons through the mineral structure from the point of contact to another which occurs because of the minerals’ semi-conductivity. While it is well understood that Fe(II) plays a central role in redox cycling of elements, the environmental implications of Fe(II) catalyzed recrystallization need to be further explored. Here, we provide evidence that the Fe mineral conductivity underpinning Fe(II) catalyzed recrystallization can couple the reduction of Cr, a priority metal contaminant, with an electron source that is cannot directly affect Cr. This is shown for both an abiotic electron source, a potentiostat, as well as the metal reducing bacteria Shewanella Putrefaciens. The implications of this work show that semiconductive minerals may be links in subsurface electrical networks that physically distribute redox chemistry and suggests novel methods for remediating Cr contamination in groundwater.

AI summary

90% confidence

MES research in electrode, membrane. Semi-conducting Fe oxide minerals, such as hematite, are well known to influence the fate of...

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 45 extracted values

Select a citation to see the quote, page and confidence behind a value.

5 of 45 extracted rows modelable

  • 23 not canonicalised (no canonical slug)
  • 16 no SI value
  • 1 contradicts other papers
ParameterValueUnitConfidenceSourceNotesModelable
Applied Potential-1,000mV vs. Ag/AgCl100%
potentiostatic control
"It was controlled using a Python script to poise the hematite working electrode …" · pH(an)=7.1Excluded: no SI value
Substrate Concentration14.3µM100%
icp-ms
"Experiment B: Initial Cr Concentration (µM) 14.3+/-0.8" · pH(an)=7.1, startupExcluded: no SI value
Acclimation Time16h100%
extracted
"S. Putrefaciens, strain CN-32 (ATCC), was grown up from 50% glycerol stocks froz…" · substrate=tryptic_soy_brothExcluded: contradicts other papers
pH7.1—100%
extracted
"Initial experimental pHs were 7.1 ± 0.2" · pH(an)=7.1, startupModelable
Membrane Pore Size0.22µm100%
extracted
"Aqueous samples collected from biotic experiments were filtered on 0.22 um PES s…" · condition_hint=biotic experiments, sample preparationModelable
Autoclave sterilization temperature121°C100%
extracted
"All solutions used in biotic experiments were autoclaved at 121 °C prior to use" · T=121°CExcluded: not canonicalised (no canonical slug)
Substrate Concentration11.8µM100%
icp-ms
"Experiment C: Initial Cr Concentration (µM) 11.8+/-2.0" · pH(an)=7.1, startupExcluded: no SI value
Acetic Acid Concentration10mM100%
extracted
"Bacteria were provided 10 mM lactate as a carbon source" · pH(an)=7.1, substrate=lactate, startupExcluded: no SI value
HCl concentration for acidification6N100%
extracted
"All samples were acidified within 12 hours after collection by the addition of 3…" · condition_hint=sample preparationExcluded: not canonicalised (no canonical slug)
Buffer Concentration50mM100%
extracted
"A background basal salts solution (BSS) with a 50 mM sodium PIPES buffer concent…" · pH(an)=7.1, startupExcluded: no SI value
Electron beam current2.5nA100%
electron microprobe
"The electron beam current was 2.5nA" · condition_hint=electron microprobe analysis, electrode_material=hematiteExcluded: not canonicalised (no canonical slug)
External Load100Ω100%
extracted
"the graphite and hematite electrodes were simply connected with a 100 Ω resistor" · pH(an)=7.1, substrate=lactateModelable
Substrate Concentration22.5µM100%
icp-ms
"Experiment D: Initial Cr Concentration (µM) 22.5+/-1.1" · pH(an)=7.1, substrate=lactate, startupExcluded: no SI value
Ethanol concentration for sterilization70%100%
extracted
"all experimental surfaces (electrodes, chamber interiors, cation exchange membra…" · condition_hint=biotic experiments, sterilization procedureExcluded: not canonicalised (no canonical slug)
Electron Transfer Rate583µmol95%
chronoamperometry, trapezoidal integration
"Experiment C: Measured e- transfer (µmol) 583" · pH(an)=7.1, steady_stateExcluded: no SI value
Fe(II) released46µmol95%
ferrozine method
"Expt A, which used no Cr, and Expt. C, which used Cr and a thin section hematite…" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Transferred electrons1,840µmol95%
chronoamperometry, trapezoidal integration
"significantly larger transferred electrons (A: 1842, B: 215, C: 1277 µmol electr…" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Transferred electrons215µmol95%
chronoamperometry, trapezoidal integration
"significantly larger transferred electrons (A: 1842, B: 215, C: 1277 µmol electr…" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Cr/Fe ratio0.53—95%
xps
"Cr/Fe ratios ranged from 0.00 (i.e. no Cr) to 0.53 in the reacted thin electrode…" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Cr/Fe ratio0—95%
xps
"Cr/Fe ratios ranged from 0.00 (i.e. no Cr) to 0.53 in the reacted thin electrode…" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Electron Transfer Rate10.5µmol95%
chronoamperometry, trapezoidal integration
"Experiment D: Measured e- transfer (µmol) 10.5" · pH(an)=7.1, substrate=lactate, steady_stateExcluded: no SI value
Electrons transfer implied by Cr reduction16.5µmol95%
calculated from cr reduction stoichiometry
"Experiment D: e- transfer implied by Cr reduction (µmol) 16.5" · pH(an)=7.1, substrate=lactate, steady_stateExcluded: not canonicalised (no canonical slug)
Glove bag H₂ concentration2%95%
extracted
"all experiments were performed in an anoxic glove bag (CoyLabs, 2-3% H2, balance…" · condition_hint=all experiments, anoxic glove bag composition, lower boundExcluded: not canonicalised (no canonical slug)
Electron Transfer Rate79.4µmol95%
chronoamperometry, trapezoidal integration
"Experiment B: Measured e- transfer (µmol) 79.4" · pH(an)=7.1, steady_stateExcluded: no SI value
Fe(II) released12µmol95%
ferrozine method
"when compared to the experiment B (12 µmol)" · pH(an)=7.1, steady_stateExcluded: not canonicalised (no canonical slug)
Showing 25 of 45

Methodology

What was the system and how was it run

Methodology

Methodology

The study employed a semi-conducting hematite electrode to investigate the reduction of chromium via Fe(II) catalyzed recrystallization, a process where electrons are conducted through the mineral structure from the point of contact to another.

Biological parameters

FieldValue
dominant species["Shewanella"]

Operating conditions

12 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-0f48fc6d2487aaa1—7.1—lactate———100——
v2-16020a16378552f7—7.1————startup—-1—
v2-83def1f813a9e87c1217.1——————-1—
v2-8e3a26cee6eaa23a—7.1—lactate——startup100——
v2-b7677222bb38d839———tryptic_soy_broth——————
v2-bce10c4efc9c9e85—7.1————steady_state—-1—
v2-d04e807c15b8bbde————————-1—
v2-d21a1ec8debb95fe121—————————
v2-d636e68775bb6e2d—7.1—lactate——steady_state100——
v2-e60042627ed9e24c—7.1————startup———
v2-f4f2af27eb8d72a3—7.1——————-1—
v2-f586e9af22985397——————————

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

13%

Fraction of expected parameters extracted

Data completeness

30%

Overall extraction coverage across fields

AI confidence

90%

Model self-reported confidence

Mean parameter confidence

96%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.

MERC
System
45
Extracted values
2020
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Keywords

  • Hematite
  • Redox
  • Shewanella putrefaciens
  • Shewanella oneidensis
  • Anoxic waters
  • Chromium

Cite

Michael Chen, Neha Mehta, Benjamin D. Kocar (2020). Chromium Reduction via a Semi-Conducting Hematite Electrode: Implications for Microbial Cycling of Metals in Natural Soils. ChemRxiv. https://doi.org/10.26434/chemrxiv.13275005.v1

Journal
ChemRxiv