Research

Paper · MES

Freestanding and flexible graphene papers as bioelectrochemical cathode for selective and efficient CO2 conversion

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 100%Electrosynthesis

Abstract

Abstract During microbial electrosynthesis (MES) driven CO 2 reduction, cathode plays a vital role by donating electrons to microbe. Here, we exploited the advantage of reduced graphene oxide (RGO) paper as novel cathode material to enhance electron transfer between the cathode and microbe, which in turn facilitated CO 2 reduction. The acetate production rate of Sporomusa ovata -driven MES reactors was 168.5 ± 22.4 mmol m −2 d −1 with RGO paper cathodes poised at −690 mV versus standard hydrogen electrode. This rate was approximately 8 fold faster than for carbon paper electrodes of the same dimension. The current density with RGO paper cathodes of 2580 ± 540 mA m −2 was increased 7 fold compared to carbon paper cathodes. This also corresponded to a better cathodic current response on their cyclic voltammetric curves. The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.3% with RGO paper cathodes and 83.8 ± 4.2% with carbon paper cathodes, respectively. Furthermore, more intensive cell attachment was observed on RGO paper electrodes than on carbon paper electrodes with confocal laser scanning microscopy and scanning electron microscopy. These results highlight the potential of RGO paper as a promising cathode for MES from CO 2 .

AI summary

100% confidence

BES research focusing on electrode, bacteria, power. Abstract During microbial electrosynthesis (MES) driven CO 2 reduction, cathode plays a vital role by donating electrons to microbe. Here, we exploi...

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 31 extracted values

Select a citation to see the quote, page and confidence behind a value.

12 of 30 extracted rows modelable

  • 11 not canonicalised (no canonical slug)
  • 5 no SI value
  • 2 verifier rejected the value
ParameterValueUnitConfidenceSourceNotesModelable
Substrateacetate—80%
llm
Coulombic efficiency90.7%98%
extracted
"The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.…" · substrate=CO2, batchModelable
Current Density (Areal)2,580mA m⁻²98%
extracted
"The current density with RGO paper cathodes of 2580 ± 540 mA m−2 was increased 7…" · substrate=CO2, batchModelable
Coulombic efficiency90.7%95%
potentiostat
"The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.…" · T=25°C, substrate=co2Modelable
Coulombic efficiency83.8%95%
potentiostat
"Coulombic efficiency for the conversion of electrons into acetate was 90.7 ± 9.3…" · T=25°C, substrate=co2Modelable
Current Density (Areal)2,580mA m⁻²95%
potentiostat
"The current density with RGO paper cathodes of 2580 ± 540 mA m−2 was increased 7…" · T=25°C, substrate=co2Modelable
Specific Surface Area0.29m² g⁻¹95%
bet method
"The specific surface area measured by the BET method of the RGO paper cathode wa…" · electrode_material=RGO paperModelable
SEM accelerating voltage10Outside physical range, check sourcekV95%
sem
"Nitrogen-dried samples were observed with a Quanta 200 FEG scanning electron mic…" · condition_hint=SEM analysis parametersExcluded: not canonicalised (no canonical slug)
Acetate Production Rate20.9mmol m⁻² d⁻¹95%
hplc
"With a carbon paper cathode poised at −690 mV versus standard hydrogen electrode…" · T=25°C, substrate=co2Excluded: no SI value
Electrode Surface Area0.36mm95%
extracted
"During the fabrication process, the thickness of RGO paper was controlled at 0.3…" · electrode_material=RGO paperExcluded: no SI value
Electrode Surface Area4cm95%
extracted
"The diameter of 4 cm was also the same for both types of cathode" · electrode_material=RGO paperExcluded: no SI value
Reactor Volume250ml95%
extracted
"The RGO paper or carbon paper cathode (4 cm diameter, 0.36–0.37 mm thickness) an…" · condition_hint=per chamber volumeModelable
Electrode Surface Area36cm²95%
extracted
"The RGO paper or carbon paper cathode (4 cm diameter, 0.36–0.37 mm thickness) an…" · condition_hint=anode material, electrode_material=graphite stickModelable
Cathode Potential-690mV vs SHE95%
extracted
"the cathode potential was set at −690 mV versus SHE during MES" · T=25°C, substrate=co2Modelable
Cyclic Voltammetry Scan Rate1mV s⁻¹95%
cyclic voltammetry
"During the CV experiments, the tested electrodes were scanned at a rate of 1 mV …" · condition_hint=cyclic voltammetry parametersModelable
Current Density (Areal)370mA m⁻²95%
potentiostat
"The current density of 2580 ± 540 mA m−2 was 7 fold higher with the RGO paper ca…" · T=25°C, substrate=co2Excluded: verifier rejected the value
CV potential window lower-1,000mV vs Ag/AgCl95%
cyclic voltammetry
"During the CV experiments, the tested electrodes were scanned at a rate of 1 mV …" · condition_hint=cyclic voltammetry parametersExcluded: not canonicalised (no canonical slug)
GO solution volume50ml95%
extracted
"Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paperExcluded: not canonicalised (no canonical slug)
HPLC column temperature30°C95%
hplc
"Acetate concentration were measured by high-performance liquid chromatography (H…" · T=30°CExcluded: not canonicalised (no canonical slug)
SEM fixation time5hours95%
sem
"For Scanning Electron Microscopy (SEM) images, cathode samples were collected an…" · pH(an)=7Excluded: not canonicalised (no canonical slug)
GO solution concentration1mg/ml95%
extracted
"Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paperExcluded: not canonicalised (no canonical slug)
HPLC mobile phase flow rate0.6ml/min95%
hplc
"The mobile phase was 5 mM H2SO4 at a flow rate of 0.6 ml/min." · condition_hint=HPLC analysis conditionsExcluded: not canonicalised (no canonical slug)
RGO paper annealing temperature200°C95%
extracted
"After cooling to room temperature, RGO paper was washed with Milli-Q water sever…" · T=200°CExcluded: not canonicalised (no canonical slug)
RGO paper reduction temperature180°C95%
extracted
"To this end, the GO paper was put in an autoclave container along with a few dro…" · T=180°CExcluded: not canonicalised (no canonical slug)
GO sonication time15minutes95%
extracted
"Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paperExcluded: not canonicalised (no canonical slug)
Showing 25 of 31

Methodology

What was the system and how was it run

Methodology

Methodology

The researchers used reduced graphene oxide (RGO) paper as a novel cathode material in microbial electrosynthesis (MES) to enhance electron transfer between the cathode and microbe, facilitating CO2 reduction.

Electrode specifications

FieldValue
materials["carbon paper","graphene"]

Performance metrics

FieldValue
citation count59

Operational parameters

FieldValue
substrate["acetate"]

Operating conditions

10 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-2b65ad59ab9af497—7————————
v2-2f1affd72d0147e930—————————
v2-4839a672ff5f3c1225——co2————-0.9—
v2-767c5724b5396ae4———CO2——batch———
v2-91288eae88e45aa2200—————————
v2-bc256c0e4b190ecd25——co2————-0.69—
v2-ca4428dc19641a8e25——co2——————
v2-cb1c48b5114799771807————————
v2-e1483871c9e90a49180—————————
v2-f586e9af22985397——————————

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

38%

Fraction of expected parameters extracted

Data completeness

50%

Overall extraction coverage across fields

AI confidence

100%

Model self-reported confidence

Mean parameter confidence

92%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic microbial electrochemical system

Representative microbial electrochemical system — matched on the paper’s system type only, not its reactor or geometry.

MES
System
2.58amperes per square metre
Best result · Current density
best of 5
31
Extracted values
2017
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Organisms · 1

Keywords

  • Graphene
  • Cathode
  • Nanotechnology

Cite

Nabin Aryal, Arnab Halder, Minwei Zhang et al. (2017). Freestanding and flexible graphene papers as bioelectrochemical cathode for selective and efficient CO2 conversion. Scientific Reports. https://doi.org/10.1038/s41598-017-09841-7

Open in lab for full controls, parameter editing, and template overlays.

Open in lab