Paper · MES
Freestanding and flexible graphene papers as bioelectrochemical cathode for selective and efficient CO2 conversion
Summary
What the paper reports, in its own words.
Abstract
Abstract During microbial electrosynthesis (MES) driven CO 2 reduction, cathode plays a vital role by donating electrons to microbe. Here, we exploited the advantage of reduced graphene oxide (RGO) paper as novel cathode material to enhance electron transfer between the cathode and microbe, which in turn facilitated CO 2 reduction. The acetate production rate of Sporomusa ovata -driven MES reactors was 168.5 ± 22.4 mmol m −2 d −1 with RGO paper cathodes poised at −690 mV versus standard hydrogen electrode. This rate was approximately 8 fold faster than for carbon paper electrodes of the same dimension. The current density with RGO paper cathodes of 2580 ± 540 mA m −2 was increased 7 fold compared to carbon paper cathodes. This also corresponded to a better cathodic current response on their cyclic voltammetric curves. The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.3% with RGO paper cathodes and 83.8 ± 4.2% with carbon paper cathodes, respectively. Furthermore, more intensive cell attachment was observed on RGO paper electrodes than on carbon paper electrodes with confocal laser scanning microscopy and scanning electron microscopy. These results highlight the potential of RGO paper as a promising cathode for MES from CO 2 .
AI summary
100% confidenceBES research focusing on electrode, bacteria, power. Abstract During microbial electrosynthesis (MES) driven CO 2 reduction, cathode plays a vital role by donating electrons to microbe. Here, we exploi...
Generated by MESSAI extraction pipeline · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 31 extracted values
Select a citation to see the quote, page and confidence behind a value.
12 of 30 extracted rows modelable
- 11 not canonicalised (no canonical slug)
- 5 no SI value
- 2 verifier rejected the value
| Parameter | Value | Unit | Confidence | Source | Notes | Modelable |
|---|---|---|---|---|---|---|
| Substrate | acetate | — | 80% | llm | ||
| Coulombic efficiency | 90.7 | % | 98% | extracted | "The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.…" · substrate=CO2, batch | Modelable |
| Current Density (Areal) | 2,580 | mA m⁻² | 98% | extracted | "The current density with RGO paper cathodes of 2580 ± 540 mA m−2 was increased 7…" · substrate=CO2, batch | Modelable |
| Coulombic efficiency | 90.7 | % | 95% | potentiostat | "The coulombic efficiency for the electrons conversion into acetate was 90.7 ± 9.…" · T=25°C, substrate=co2 | Modelable |
| Coulombic efficiency | 83.8 | % | 95% | potentiostat | "Coulombic efficiency for the conversion of electrons into acetate was 90.7 ± 9.3…" · T=25°C, substrate=co2 | Modelable |
| Current Density (Areal) | 2,580 | mA m⁻² | 95% | potentiostat | "The current density with RGO paper cathodes of 2580 ± 540 mA m−2 was increased 7…" · T=25°C, substrate=co2 | Modelable |
| Specific Surface Area | 0.29 | m² g⁻¹ | 95% | bet method | "The specific surface area measured by the BET method of the RGO paper cathode wa…" · electrode_material=RGO paper | Modelable |
| SEM accelerating voltage | 10Outside physical range, check source | kV | 95% | sem | "Nitrogen-dried samples were observed with a Quanta 200 FEG scanning electron mic…" · condition_hint=SEM analysis parameters | Excluded: not canonicalised (no canonical slug) |
| Acetate Production Rate | 20.9 | mmol m⁻² d⁻¹ | 95% | hplc | "With a carbon paper cathode poised at −690 mV versus standard hydrogen electrode…" · T=25°C, substrate=co2 | Excluded: no SI value |
| Electrode Surface Area | 0.36 | mm | 95% | extracted | "During the fabrication process, the thickness of RGO paper was controlled at 0.3…" · electrode_material=RGO paper | Excluded: no SI value |
| Electrode Surface Area | 4 | cm | 95% | extracted | "The diameter of 4 cm was also the same for both types of cathode" · electrode_material=RGO paper | Excluded: no SI value |
| Reactor Volume | 250 | ml | 95% | extracted | "The RGO paper or carbon paper cathode (4 cm diameter, 0.36–0.37 mm thickness) an…" · condition_hint=per chamber volume | Modelable |
| Electrode Surface Area | 36 | cm² | 95% | extracted | "The RGO paper or carbon paper cathode (4 cm diameter, 0.36–0.37 mm thickness) an…" · condition_hint=anode material, electrode_material=graphite stick | Modelable |
| Cathode Potential | -690 | mV vs SHE | 95% | extracted | "the cathode potential was set at −690 mV versus SHE during MES" · T=25°C, substrate=co2 | Modelable |
| Cyclic Voltammetry Scan Rate | 1 | mV s⁻¹ | 95% | cyclic voltammetry | "During the CV experiments, the tested electrodes were scanned at a rate of 1 mV …" · condition_hint=cyclic voltammetry parameters | Modelable |
| Current Density (Areal) | 370 | mA m⁻² | 95% | potentiostat | "The current density of 2580 ± 540 mA m−2 was 7 fold higher with the RGO paper ca…" · T=25°C, substrate=co2 | Excluded: verifier rejected the value |
| CV potential window lower | -1,000 | mV vs Ag/AgCl | 95% | cyclic voltammetry | "During the CV experiments, the tested electrodes were scanned at a rate of 1 mV …" · condition_hint=cyclic voltammetry parameters | Excluded: not canonicalised (no canonical slug) |
| GO solution volume | 50 | ml | 95% | extracted | "Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paper | Excluded: not canonicalised (no canonical slug) |
| HPLC column temperature | 30 | °C | 95% | hplc | "Acetate concentration were measured by high-performance liquid chromatography (H…" · T=30°C | Excluded: not canonicalised (no canonical slug) |
| SEM fixation time | 5 | hours | 95% | sem | "For Scanning Electron Microscopy (SEM) images, cathode samples were collected an…" · pH(an)=7 | Excluded: not canonicalised (no canonical slug) |
| GO solution concentration | 1 | mg/ml | 95% | extracted | "Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paper | Excluded: not canonicalised (no canonical slug) |
| HPLC mobile phase flow rate | 0.6 | ml/min | 95% | hplc | "The mobile phase was 5 mM H2SO4 at a flow rate of 0.6 ml/min." · condition_hint=HPLC analysis conditions | Excluded: not canonicalised (no canonical slug) |
| RGO paper annealing temperature | 200 | °C | 95% | extracted | "After cooling to room temperature, RGO paper was washed with Milli-Q water sever…" · T=200°C | Excluded: not canonicalised (no canonical slug) |
| RGO paper reduction temperature | 180 | °C | 95% | extracted | "To this end, the GO paper was put in an autoclave container along with a few dro…" · T=180°C | Excluded: not canonicalised (no canonical slug) |
| GO sonication time | 15 | minutes | 95% | extracted | "Briefly, 50 ml of a 1 mg/ml GO solution was sonicated for 15 minutes before bein…" · condition_hint=RGO paper fabrication, electrode_material=RGO paper | Excluded: not canonicalised (no canonical slug) |
Methodology
What was the system and how was it run
Methodology
Methodology
The researchers used reduced graphene oxide (RGO) paper as a novel cathode material in microbial electrosynthesis (MES) to enhance electron transfer between the cathode and microbe, facilitating CO2 reduction.
Electrode specifications
| Field | Value |
|---|---|
| materials | ["carbon paper","graphene"] |
Performance metrics
| Field | Value |
|---|---|
| citation count | 59 |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["acetate"] |
Operating conditions
10 runs extracted| Run | T°C | pHan | pHcat | Substrate | [S]mg/L | HRTh | Mode | R_extΩ | V_appV | Inoculum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-2b65ad59ab9af497 | — | 7 | — | — | — | — | — | — | — | — |
| v2-2f1affd72d0147e9 | 30 | — | — | — | — | — | — | — | — | — |
| v2-4839a672ff5f3c12 | 25 | — | — | co2 | — | — | — | — | -0.9 | — |
| v2-767c5724b5396ae4 | — | — | — | CO2 | — | — | batch | — | — | — |
| v2-91288eae88e45aa2 | 200 | — | — | — | — | — | — | — | — | — |
| v2-bc256c0e4b190ecd | 25 | — | — | co2 | — | — | — | — | -0.69 | — |
| v2-ca4428dc19641a8e | 25 | — | — | co2 | — | — | — | — | — | — |
| v2-cb1c48b511479977 | 180 | 7 | — | — | — | — | — | — | — | — |
| v2-e1483871c9e90a49 | 180 | — | — | — | — | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
38%
Fraction of expected parameters extracted
Data completeness
50%
Overall extraction coverage across fields
AI confidence
100%
Model self-reported confidence
Mean parameter confidence
92%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Source PDF
The paper as published.
Representative model, generic microbial electrochemical system
Tap to interactRepresentative model, generic microbial electrochemical system
Representative microbial electrochemical system — matched on the paper’s system type only, not its reactor or geometry.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 1
Keywords
- Graphene
- Cathode
- Nanotechnology
Cite
Nabin Aryal, Arnab Halder, Minwei Zhang et al. (2017). Freestanding and flexible graphene papers as bioelectrochemical cathode for selective and efficient CO2 conversion. Scientific Reports. https://doi.org/10.1038/s41598-017-09841-7
- Journal
- Scientific Reports
Open in lab for full controls, parameter editing, and template overlays.
Open in lab