Electrochemical (bio-)sensors operating in human physiological fluids
Summary
What the paper reports, in its own words.
Abstract
This thesis is focused on developing electrochemical (bio-)sensors specifically designed to detect biomolecules and bacteria in human physiological fluids. A more comprehensive understanding of their performance can be obtained by exposing the sensors to real human physiological fluids. Thus, four biosensors were designed and tested in saliva, plasma, blood, and urine. Specifically, a voltammetric electronic tongue, integrating six different electrode materials, was developed to qualitatively assess SARS-CoV-2 in saliva samples using principal component analysis. A tubular enzyme-based sensor utilizing incorporated cellobiose dehydrogenase in an Os(bpy)PVI redox polymer was employed for continuous glucose sensing in human plasma and undiluted whole blood under homeostatic conditions. Two different sensing concepts were developed for the label-free detection of bacteria (Escherichia coli, Enterococcus faecalis, and Klebsiella pneumoniae) in artificial urine and human urine based on metabolic activity due to bacterial growth. The first sensor enabled continuous bacterial detection by reducing Prussian Blue deposited on screen-printed electrodes with wireless data transfer. The second bacterial-sensitive sensor utilized electrochemical characterization to identify three bacteria types based on artificial urine metabolic changes. For a qualitative investigation of the metabolic changes, nuclear magnetic resonance was utilized, and flow cytometry was used to quantify and correlate bacterial growth with electrochemistry. Multivariate statistical data analysis was applied to distinguish bacteria-free and bacteria-infected artificial urine. Finally, an overview of the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz., tears, sweat, saliva, and urine, was give
AI summary
90% confidenceMES research in electrode, bacteria. This thesis is focused on developing electrochemical (bio-)sensors specifically designed to ...
Generated by MESSAI extraction pipeline · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 98 extracted values
Select a citation to see the quote, page and confidence behind a value.
0 of 97 extracted rows modelable
- 92 not canonicalised (no canonical slug)
- 5 no SI value
| Parameter | Value | Unit | Confidence | Source | Notes | Modelable |
|---|---|---|---|---|---|---|
| Substrate | glucose,urine | — | 80% | llm | ||
| Reactor type | tubular | — | 80% | extracted | Excluded: not canonicalised (no canonical slug) | |
| Dominant organism | Escherichia | — | 80% | extracted | Excluded: not canonicalised (no canonical slug) | |
| Filter Window | 860 | samples | 50% | extracted | Excluded: no SI value | |
| Short Circuit Current | 150 | A | 50% | extracted | Excluded: no SI value | |
| Current Sharing | 80 | % | 50% | extracted | Excluded: no SI value | |
| Mixing Time | 10 | s | 50% | extracted | Excluded: no SI value | |
| Vibration Amplitude | 3 | mm | 50% | extracted | Excluded: no SI value | |
| All electrodes had tubular geometry with douter | 3 | mm | 50% | extracted | "All electrodes had tubular geometry with douter = 3 mm" | Excluded: not canonicalised (no canonical slug) |
| the residual current response | 80 | % | 50% | extracted | "the residual current response was 80%" | Excluded: not canonicalised (no canonical slug) |
| and dinner | 1 | mm | 50% | extracted | "and dinner = 1 mm" | Excluded: not canonicalised (no canonical slug) |
| The spectra were acquired with the following parameters | 150 | a | 50% | extracted | "The spectra were acquired with the following parameters: 150 …" | Excluded: not canonicalised (no canonical slug) |
| Dashed | 40 | s | 50% | extracted | "dashed = 40 s" | Excluded: not canonicalised (no canonical slug) |
| version rate | 860 | samples | 50% | extracted | "version rate was 860 samples" | Excluded: not canonicalised (no canonical slug) |
| Optimum | 55 | mm | 50% | extracted | "optimum is 50–60 mm" | Excluded: not canonicalised (no canonical slug) |
| Solid | 10 | s | 50% | extracted | "solid = 10 s" | Excluded: not canonicalised (no canonical slug) |
| Dotted | 100 | s | 50% | extracted | "dotted = 100 s" | Excluded: not canonicalised (no canonical slug) |
| Fluids | — | — | 0% | extracted | "fluids is demanding," | Excluded: not canonicalised (no canonical slug) |
| Sample | — | — | 0% | extracted | "sample is required," | Excluded: not canonicalised (no canonical slug) |
| Norepinephrine | — | — | 0% | extracted | "norepinephrine is high enough for detection," | Excluded: not canonicalised (no canonical slug) |
| This | — | — | 0% | extracted | "this is likely to increase during psychological and physical challenges," | Excluded: not canonicalised (no canonical slug) |
| Photoresist | — | — | 0% | extracted | "photoresist is developed;" | Excluded: not canonicalised (no canonical slug) |
| Saliva | — | — | 0% | extracted | "saliva is a clear," | Excluded: not canonicalised (no canonical slug) |
| Cells | — | — | 0% | extracted | "cells is possible," | Excluded: not canonicalised (no canonical slug) |
| Hepatit | — | — | 0% | extracted | "hepatitis A," | Excluded: not canonicalised (no canonical slug) |
Methodology
What was the system and how was it run
Methodology
Methodology
Four electrochemical biosensors were designed and tested in human physiological fluids (saliva, plasma, blood, and urine) to assess their performance and detect biomolecules and bacteria.
Biological parameters
| Field | Value |
|---|---|
| dominant species | ["Escherichia","Klebsiella"] |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["glucose","urine"] |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
38%
Fraction of expected parameters extracted
Data completeness
50%
Overall extraction coverage across fields
AI confidence
90%
Model self-reported confidence
Mean parameter confidence
10%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 1
Keywords
- Biosensor
- Saliva
- Potentiostat
- Chromatography
- Bacterial growth
- Bacteria
Cite
Carolin Psotta (2023). Electrochemical (bio-)sensors operating in human physiological fluids. https://doi.org/10.24834/isbn.9789178773992
- Journal
- Journal not recorded