Paper
Revisiting methods to characterize bioelectrochemical systems: The influence of uncompensated resistance (iR-drop), double layer capacitance, and junction potential
Summary
What the paper reports, in its own words.
AI summary
85% confidenceThe paper revisits methods to characterize bioelectrochemical systems, highlighting the influence of uncompensated resistance, double layer capacitance, and junction potential on system performance.
Generated by MESSAI extraction pipeline · review against source PDF
Key findings
- Uncompensated resistance significantly affects bioelectrochemical system performance, leading to inaccurate measurements and conclusions.
- Double layer capacitance and junction potential also impact system performance, but to a lesser extent than uncompensated resistance.
- A new method is proposed to account for these effects and improve system characterization.
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
Methodology
What was the system and how was it run
Methodology
Methodology
The authors employed a combination of experimental and theoretical approaches to investigate the impact of uncompensated resistance, double layer capacitance, and junction potential on bioelectrochemical system performance.
Performance metrics
| Field | Value |
|---|---|
| citation count | 42 |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
13%
Fraction of expected parameters extracted
Data completeness
30%
Overall extraction coverage across fields
AI confidence
85%
Model self-reported confidence
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.
Keywords
- Capacitance
- Chronoamperometry
- Linear sweep voltammetry
- Cyclic voltammetry
- Double-layer capacitance
- Electrode
Cite
J. Madjarov, S.C. Popat, J. Erben et al. (2017). Revisiting methods to characterize bioelectrochemical systems: The influence of uncompensated resistance (iR-drop), double layer capacitance, and junction potential. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2017.03.033
- Journal
- Journal of Power Sources