Research

Paper · MNRC

Electrochemical and bioelectrochemical ammonium recovery from N-loaded streams using a hydrophobic membrane.

01

Summary

What the paper reports, in its own words.

AI Enhanced· 75%Wastewater TreatmentResource Recovery

Abstract

Bioelectrochemical systems enable the recovery of ammonium from wastewater with low energy requirements and as a concentrated nitrogen-rich stream. This work aims to thoroughly investigate different cathodic electrode configurations and to optimize the operational conditions for active ammonium recovery from synthetic wastewater as concentrated ammonium sulphate. Different applied current intensities (50 mA, corresponding to 5 A m -2 , and 75 mA, corresponding to 7.5 A m -2 ) and initial ammonium concentrations (between 0.3 and 3 g L -1 N-NH 4 + ) were tested in an abiotic electrochemical system to understand the upper threshold of the used three-chamber configuration with hydrophobic membrane in terms of ammonium recovery rate (R rec ). With an external current of 75 mA, the highest value was 55 gN-NH 4 + m -2 d -1 when removing 97 % from an initial ammonium concentration of 3 g L -1 . Bioelectrochemical ammonium removal/recovery was evaluated under different applied potentials (0.8, 1.0, 1.2, and 1.4 V) using two configurations: a Nickel-based gas diffusion electrode (GDE) and a configuration with the cathode (stainless steel or nickel foam) physically separated from the hydrophobic membrane. The highest removal rate (R rem ) (21 gN-NH 4 + m -2 d -1 ) was exhibited for stainless steel cathode at 1.4 V mainly due to its higher current density, which increased the cations migration. This higher R rem also led to a higher R rec (17 gN-NH 4 + m -2 d -1 ).

AI summary: matches the abstract (75% confidence) · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 8 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 8 extracted rows modelable

  • 3 not canonicalised (no canonical slug)
  • 5 no SI value
ParameterValueUnitConfidenceSourceModelable
Reactor typethree-chamber—80%
extracted
Excluded: not canonicalised (no canonical slug)
Chambers3—80%
extracted
Excluded: not canonicalised (no canonical slug)
Substratewastewater—70%
extracted
Excluded: no SI value
Electrode materialstainless steel—50%
extracted
Excluded: not canonicalised (no canonical slug)
Cathode materialstainless steel or nickel foam—50%
extracted
Excluded: no SI value
Maximum Current Density7,500mA/m²50%
extracted
Excluded: no SI value
Substrateammonium—50%
extracted
Excluded: no SI value
Membrane materialhydrophobic membrane—50%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

The study employed a three-chamber configuration with a hydrophobic membrane and tested various operational conditions, including applied current intensities and initial ammonium concentrations, to optimize ammonium recovery

Electrode specifications

FieldValue
materials["stainless steel","nickel"]

Operational parameters

FieldValue
substrate["wastewater"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

38%

Fraction of expected parameters extracted

Data completeness

50%

Overall extraction coverage across fields

AI confidence

75%

Model self-reported confidence

Mean parameter confidence

60%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.

MNRC
System
7.50amperes per square metre
Best result · Current density
8
Extracted values
2025
Year

Keywords

  • Ammonium recovery
  • Cation exchange membrane
  • Hydrophobic membrane
  • Microbial electrolysis cell
  • Ni foam
  • Stainless steel

Cite

(2025). Electrochemical and bioelectrochemical ammonium recovery from N-loaded streams using a hydrophobic membrane. Bioelectrochemistry (Amsterdam, Netherlands). https://doi.org/10.1016/j.bioelechem.2025.109013

PubMed
40513371