Paper · MNRC
Electrochemical and bioelectrochemical ammonium recovery from N-loaded streams using a hydrophobic membrane.
Summary
What the paper reports, in its own words.
Abstract
Bioelectrochemical systems enable the recovery of ammonium from wastewater with low energy requirements and as a concentrated nitrogen-rich stream. This work aims to thoroughly investigate different cathodic electrode configurations and to optimize the operational conditions for active ammonium recovery from synthetic wastewater as concentrated ammonium sulphate. Different applied current intensities (50 mA, corresponding to 5 A m -2 , and 75 mA, corresponding to 7.5 A m -2 ) and initial ammonium concentrations (between 0.3 and 3 g L -1 N-NH 4 + ) were tested in an abiotic electrochemical system to understand the upper threshold of the used three-chamber configuration with hydrophobic membrane in terms of ammonium recovery rate (R rec ). With an external current of 75 mA, the highest value was 55 gN-NH 4 + m -2 d -1 when removing 97 % from an initial ammonium concentration of 3 g L -1 . Bioelectrochemical ammonium removal/recovery was evaluated under different applied potentials (0.8, 1.0, 1.2, and 1.4 V) using two configurations: a Nickel-based gas diffusion electrode (GDE) and a configuration with the cathode (stainless steel or nickel foam) physically separated from the hydrophobic membrane. The highest removal rate (R rem ) (21 gN-NH 4 + m -2 d -1 ) was exhibited for stainless steel cathode at 1.4 V mainly due to its higher current density, which increased the cations migration. This higher R rem also led to a higher R rec (17 gN-NH 4 + m -2 d -1 ).
AI summary: matches the abstract (75% confidence) · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 8 extracted values
Select a citation to see the quote, page and confidence behind a value.
0 of 8 extracted rows modelable
- 3 not canonicalised (no canonical slug)
- 5 no SI value
| Parameter | Value | Unit | Confidence | Source | Modelable |
|---|---|---|---|---|---|
| Reactor type | three-chamber | — | 80% | extracted | Excluded: not canonicalised (no canonical slug) |
| Chambers | 3 | — | 80% | extracted | Excluded: not canonicalised (no canonical slug) |
| Substrate | wastewater | — | 70% | extracted | Excluded: no SI value |
| Electrode material | stainless steel | — | 50% | extracted | Excluded: not canonicalised (no canonical slug) |
| Cathode material | stainless steel or nickel foam | — | 50% | extracted | Excluded: no SI value |
| Maximum Current Density | 7,500 | mA/m² | 50% | extracted | Excluded: no SI value |
| Substrate | ammonium | — | 50% | extracted | Excluded: no SI value |
| Membrane material | hydrophobic membrane | — | 50% | extracted | Excluded: no SI value |
Methodology
What was the system and how was it run
Methodology
Methodology
The study employed a three-chamber configuration with a hydrophobic membrane and tested various operational conditions, including applied current intensities and initial ammonium concentrations, to optimize ammonium recovery
Electrode specifications
| Field | Value |
|---|---|
| materials | ["stainless steel","nickel"] |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["wastewater"] |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
38%
Fraction of expected parameters extracted
Data completeness
50%
Overall extraction coverage across fields
AI confidence
75%
Model self-reported confidence
Mean parameter confidence
60%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.
Keywords
- Ammonium recovery
- Cation exchange membrane
- Hydrophobic membrane
- Microbial electrolysis cell
- Ni foam
- Stainless steel
Cite
(2025). Electrochemical and bioelectrochemical ammonium recovery from N-loaded streams using a hydrophobic membrane. Bioelectrochemistry (Amsterdam, Netherlands). https://doi.org/10.1016/j.bioelechem.2025.109013
- PubMed
- 40513371