Ammonia removal from wastewater was successfully achieved by simultaneous nitrification and denitrification (SND) in a double-chamber microbial electrolysis cell (MEC). The MEC operations at different applied voltages (0.7 to 1.5 V) and initial ammonia concentrations (30 to 150 mg/L) were conducted in order to evaluate their effects on MEC performance in batch mode. The maximum nitrification efficiency of 96.8% was obtained in the anode at 1.5 V, followed by 94.11% at 1.0 V and 87.05% at 0.7. At 1.5 V, the initial ammonia concentration considerably affected the nitrification rate, and the highest nitrification rate constant of 0.1601/h was determined from a first-order linear regression at 30 mg/L ammonium nitrogen. The overall total nitrogen removal efficiency was noted to be 85% via the SND in the MEC operated at an initial ammonium concentration of 50 mg/L and an applied cell voltage of 1.5 V. The MEC operation in continuous mode could remove ammonia (50 mg/L) in a series of anode and cathode chambers at the nitrogen removal rate of 170 g-N/m3.d at an HRT of 15. This study suggests that a standalone dual-chamber MEC can efficiently remove ammonia via the SND process without needing additional organic substrate and aeration, which makes this system viable for field applications.
AI summary
82% confidenceThis dual-chamber MEC study demonstrates simultaneous nitrification and denitrification (SND) for ammonia removal without external organic substrate or aeration. Applied voltage (0.7–1.5 V) controlled dissolved oxygen generation at the anode, enabling nitrification of 30–150 mg NH₄-N/L to nitrate, which was then reduced at the biocathode. Batch mode achieved 96.8% nitrification efficiency and 85% total nitrogen removal at 1.5 V and 50 mg/L inlet ammonia. Continuous operation at 15 h HRT yielded 170 g-N/m³·d removal rate with 81% ammonia removal efficiency, demonstrating potential for field-scale wastewater treatment without supplemental carbon or aeration.
Key insights
Threshold Applied voltage directly controls DO generation rate (0.26–0.65 mg/L/h at 0.7–1.5 V), which sets the nitrification rate ceiling; higher voltage accelerates DO buildup but corrosion occurs above 2.0 V.
So what. Operators should target 1.5 V as the upper safe limit to maximize DO supply without electrode degradation; below 0.7 V, DO takes >50 h to reach the 2 mg/L nitrification threshold.
Trade-off Nitrification rate constant decreases sharply with inlet ammonia loading: 0.160 1/h at 30 mg/L vs. 0.026 1/h at 150 mg/L (6-fold drop), despite constant applied voltage.
So what. High-strength ammonia wastewater (>100 mg/L) will require proportionally longer residence times or staged reactors; single-pass treatment becomes kinetically limited.
Trade-off Nitrogen diffusion across the cation exchange membrane increases with inlet ammonia loading: 11.2% at 30 mg/L to 14.3% at 150 mg/L, reducing net removal efficiency.
So what. Ion-selective membranes or continuous-mode operation (which dilutes concentration gradients) are needed to minimize parasitic diffusion losses, especially at high inlet loads.
Mechanism Denitrifcation is oxygen-sensitive: residual nitrate (4.2 mg/L from 55 mg/L inlet) and nitrite accumulation (<2.5 mg/L) persist because DO diffusion from anode to cathode inhibits the anaerobic reduction pathway.
So what. Improve membrane selectivity or add a DO-scavenging step (e.g., L-cysteine dosing) before cathode feed to prevent oxygen cross-over and achieve >90% total nitrogen removal.
Trade-off Continuous-mode ammonia removal efficiency is HRT-dependent: 81% at 15 h HRT vs. 97.8% at 25 h HRT, indicating nitrification kinetics are flow-rate limited even at constant applied voltage.
So what. Field designs must balance throughput (170 g-N/m³·d at 15 h) against treatment quality; 20–25 h HRT is needed for >95% ammonia removal in continuous mode.
Opportunity areas6
Specific gaps in this paper, with an experiment that would close each.
High No measurement of cathode potential or anode potential independently; only cell voltage (0.7–1.5 V) is reported. Anode and cathode potentials vs. SHE are not characterized.
Section 2.2 states 'applied potential was regulated in the range 0.7 V, 1.0 V, and 1.5 V' but does not specify whether this is cell voltage or individual electrode potentials. Prior work (Zhan et al., cited) uses anodic potential of +800 mV vs. SHE; without electrode potentials, results cannot be compared or reproduced.
Try. Measure anode and cathode potential vs. Ag/AgCl reference electrode at each applied cell voltage; correlate individual potentials to nitrification and denitrification rates.
High No N₂O or N₂ quantification; only nitrate and nitrite are tracked. Denitrification pathway (N₂O vs. N₂) is not determined.
Section 3.4 reports 44.5 mg/L (80.9%) of total nitrogen 'converted to nitrogen gas' but provides no direct measurement of N₂ or N₂O. Residual 4.2 mg NO₃⁻-N/L and <2.5 mg NO₂⁻-N/L account for only ~19%, leaving 1% unaccounted for; N₂O could be a significant byproduct.
Try. Use gas chromatography or membrane inlet mass spectrometry to quantify N₂ and N₂O in cathode headspace during denitrification; determine if N₂O accumulates under high DO or low HRT conditions.
Medium Continuous-mode operation only tested at 15, 20, and 25 h HRT; no intermediate values or shorter HRTs (<15 h) explored.
Figure 7A shows ammonia removal drops to 81% at 15 h HRT but the paper does not test whether 10–12 h HRT is feasible or where the kinetic limit lies. Practical field designs need to know the minimum HRT for acceptable removal (e.g., 90%).
Try. Operate continuous mode at HRT = 10, 12, 15, 18, 20, 25 h; plot ammonia removal efficiency and nitrogen removal rate vs. HRT to identify the optimal operating window.
Medium No variation of applied voltage in continuous mode; only 1.5 V is tested. Trade-off between voltage, DO generation, and energy cost is not explored.
Batch experiments show 1.0 V achieves 94.11% nitrification efficiency vs. 96.8% at 1.5 V (only 2.7% gain), but energy cost and electrode wear are not compared. Section 3.1 notes corrosion at 2.0 V but does not quantify electrode lifetime or energy consumption.
Try. Operate continuous mode at 0.7, 1.0, 1.5 V; measure power consumption (W), electrode mass loss, and ammonia removal rate to calculate energy cost per kg N removed and electrode durability.
Medium Cation exchange membrane (CEM) is used instead of proton exchange membrane (PEM), but no comparison of nitrogen diffusion or ion selectivity between the two.
Section 2.1 states CEM was chosen for 'high rigidity, versatility, and low-cost' but Section 3.3 reports 14.3% nitrogen diffusion loss at 150 mg/L inlet. No data on whether PEM would reduce this loss or whether a more selective membrane (e.g., anion exchange) would improve denitrification.
Try. Compare CEM vs. PEM vs. anion exchange membrane (AEM) in parallel batch experiments; measure nitrogen diffusion and denitrification efficiency at 50 and 150 mg NH₄-N/L inlet.
Medium Cathode biofilm composition and denitrifier enrichment are not characterized; no molecular analysis (16S rRNA, metagenomics) or enzyme assays (nitrate reductase, nitrite reductase).
Section 2.1 states cathode was 'inoculated with sewage sludge' and 'operated for one month to develop nitrifiers at the anode and denitrifiers at the cathode' but no confirmation that autotrophic denitrifiers (as claimed in Introduction) actually colonized the cathode. Heterotrophic denitrifiers could be responsible, which would require organic carbon.
Try. Perform 16S rRNA gene sequencing on anode and cathode biofilms at steady state; quantify autotrophic vs. heterotrophic denitrifier abundance; measure nitrate reductase and nitrite reductase activity.
Generated by MESSAI extraction pipeline · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 64 extracted values
Select a citation to see the quote, page and confidence behind a value.
24 of 62 extracted rows modelable
- 10 not canonicalised (no canonical slug)
- 28 no SI value
| Parameter | Value | Unit | Confidence | Source | Notes | Modelable |
|---|---|---|---|---|---|---|
| Substrate | wastewater | — | 80% | llm | ||
| Coulombic efficiency | 96.8 | % | 80% | llm | ||
| Nitrate Consumption Rate | 0.16 | 1/h | 95% | first-order linear regression | "the highest nitrification rate constant of 0.1601/h was determined from a first-or…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Dissolved Oxygen | 3 | mg/L | 95% | do probe measurement | "the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_state | Modelable |
| Total Nitrogen Removal | 85 | % | 95% | extracted | "The overall total nitrogen removal efficiency was noted to be 85% via the SND in …" · T=35°C, substrate=ammonium, steady_state | Modelable |
| Dissolved Oxygen | 2.6 | mg/L | 95% | do probe measurement | "the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_state | Modelable |
| Dissolved Oxygen | 3.1 | mg/L | 95% | do probe measurement | "the DO concentration increased in all the conditions and finally reached to 2.6, …" · T=35°C, steady_state | Modelable |
| Ammonia Removal Efficiency | 87.1 | % | 95% | extracted | "and 87.05% at 0.7" · T=35°C, substrate=ammonium, steady_state | Modelable |
| Ammonia Removal Efficiency | 96.8 | % | 95% | extracted | "The maximum nitrification efficiency of 96.8% was obtained in the anode at 1.5 V" · T=35°C, substrate=ammonium, steady_state | Modelable |
| Ammonia Removal Efficiency | 94.1 | % | 95% | extracted | "followed by 94.11% at 1.0 V" · T=35°C, substrate=ammonium, steady_state | Modelable |
| Nitrogen Removal | 170 | g-N/m³.d | 95% | extracted | "The MEC operation in continuous mode could remove ammonia (50 mg/L) in a series …" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Ammonium-N Removed | 93.3 | % | 90% | extracted | "By the end of the operation (50 h), and 93.3% conversion of ammonium nitrogen to…" · T=35°C, substrate=ammonium, steady_state | Modelable |
| Nitrate nitrogen effluent concentration | 4.2 | mg/L | 90% | extracted | "By the end of the operation (170 h), the 55 mg/L of nitrate-nitrogen was decreas…" · T=35°C, substrate=nitrate, steady_state | Excluded: not canonicalised (no canonical slug) |
| Nitrate nitrogen concentration | 52.1 | mg/L | 90% | extracted | "The initial 55.8 mg/L of ammonium nitrogen was decreased to 0.7 mg/L, with a sim…" · T=35°C, substrate=ammonium, steady_state | Excluded: not canonicalised (no canonical slug) |
| Nitrogen Removal | 44.5 | mg/L | 90% | extracted | "Overall, 44.5 mg/L or 80.9% of total nitrogen was converted to nitrogen gas" · T=35°C, substrate=nitrate, steady_state | Excluded: no SI value |
| Nitrate Consumption Rate | 0.072 | L/h | 90% | first-order kinetics linear regression | "the computed constants with the application of 0.7 V, 1.0V, and 1.5 V, are noted…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Ammonium Ion Concentration | 13.5 | mg/L | 90% | extracted | "At 20 h, with 0.7 V, 1.0 V, and 1.5 V, the effluent ammonium nitrogen concentrati…" · T=35°C, substrate=ammonium, transient | Modelable |
| Nitrogen Removal | 149 | g-N/m³.d | 90% | extracted | "compared to what was obtained for HRT 20 (149 g-N/m3.d)" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Nitrogen Removal | 170 | g-N/m³.d | 90% | extracted | "the overall total nitrogen removal (combining SND) was noted to be higher in HRT…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Nitrate Consumption Rate | 0.044 | L/h | 90% | first-order kinetics linear regression | "the computed constants with the application of 0.7 V, 1.0V, and 1.5 V, are noted…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Nitrogen Removal | 123 | g-N/m³.d | 90% | extracted | "and HRT 25 (122.9 g-N/m3.d)" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Nitrate Consumption Rate | 0.072 | L/h | 90% | first-order kinetics | "The calculated constants from using 30, 50, and 150 mg/L of ammonium nitrogen in…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Dissolved Oxygen | 0.65 | mg/l/h | 90% | extracted | "With applied voltages of 0.7 V, 1.0 V, and 1.5 V, the DO generation rate was not…" · T=35°C | Excluded: no SI value |
| Nitrate Consumption Rate | 0.16 | L/h | 90% | first-order kinetics | "The calculated constants from using 30, 50, and 150 mg/L of ammonium nitrogen in…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
| Nitrate Consumption Rate | 0.055 | L/h | 90% | first-order kinetics linear regression | "the computed constants with the application of 0.7 V, 1.0V, and 1.5 V, are noted…" · T=35°C, substrate=ammonium, steady_state | Excluded: no SI value |
Literature priors
Against the literature
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
Methodology
What was the system and how was it run
Methodology
Methodology
The study used a dual-chamber MEC (420 mL total volume) with carbon fiber brush electrodes separated by a cation exchange membrane. Anode and cathode were inoculated with sewage sludge and acclimated for one month. Batch experiments (0.7–1.5 V, 30–150 mg NH₄-N/L inlet, 100 h cycles) evaluated nitrification kinetics and voltage effects. Continuous-mode tests (15–25 h HRT, 50 mg NH₄-N/L inlet, 200 h duration) assessed steady-state performance. Nitrogen species (NH₄-N, NO₃-N, NO₂-N, total N) were measured by spectrophotometry; dissolved oxygen by probe; pH by electrode. First-order kinetics were fitted to batch ammonia removal data.
System configuration
| Field | Value |
|---|---|
| reactor type | MEC |
| chamber config | 2-chamber |
Performance metrics
| Field | Value |
|---|---|
| coulombic efficiency | 96.8 |
| citation count | 11 |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["wastewater"] |
Operating conditions
18 runs extracted| Run | T°C | pHan | pHcat | Substrate | [S]mg/L | HRTh | Mode | R_extΩ | V_appV | Inoculum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-07462404aff92552 | 35 | — | — | — | — | — | steady_state | — | 1.5 | — |
| v2-0dc40916a0859e79 | 35 | — | — | ammonium | 50 | — | transient | — | 1.5 | — |
| v2-0f2b218262dae340 | 35 | — | — | nitrate | 55 | — | steady_state | — | 1.5 | — |
| v2-1fa4fc0f1547fe5f | 35 | — | — | ammonium | 50 | — | steady_state | — | 1.5 | — |
| v2-29a9ea4b2ddb64c8 | 35 | — | — | — | — | — | steady_state | — | 1 | — |
| v2-3392b9659210e880 | 35 | — | — | — | — | — | steady_state | — | 0.7 | — |
| v2-3e033c4f57a586c3 | 35 | — | — | ammonium | 50 | — | transient | — | 1 | — |
| v2-50ab3fec0dd51326 | 35 | — | — | ammonium | 55 | — | steady_state | — | 1.5 | — |
| v2-51f7994682633ef6 | 35 | — | — | ammonium | 150 | — | startup | — | 1.5 | — |
| v2-835d3a7ea6123e87 | 35 | — | — | ammonium | 150 | — | steady_state | — | 1.5 | — |
| v2-8575e24ce7d608e3 | 35 | — | — | ammonium | 50 | — | transient | — | 0.7 | — |
| v2-85af779d10df4270 | 35 | — | — | ammonium | 30 | — | steady_state | — | 1.5 | — |
| v2-879e8ea811691c12 | 35 | — | — | — | — | — | — | — | 1.5 | — |
| v2-a3410e2ba51bceaf | 35 | — | — | ammonium | 50 | — | steady_state | — | 0.7 | — |
| v2-b5b0df16ec94a457 | 35 | — | — | nitrate | 55 | — | — | — | 1.5 | — |
| v2-b99fd1ee41d53df3 | 35 | — | — | — | — | — | — | — | 0.7 | — |
| v2-bf7be62cb730fea1 | 35 | — | — | ammonium | 50 | — | steady_state | — | 1 | — |
| v2-eeab7128b08e1aa5 | 35 | — | — | — | — | — | — | — | 1 | — |
Outcomes
What was measured and what worked
Key takeaways
Coulombic efficiency
electrochemistry96.8percent
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
50%
Fraction of expected parameters extracted
Data completeness
70%
Overall extraction coverage across fields
AI confidence
82%
Model self-reported confidence
Mean parameter confidence
88%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Source PDF
The paper as published.
Representative model, generic MEC
Tap to interactRepresentative model, generic MEC
Representative MEC — matched on the paper’s system type only, not its reactor or geometry.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Parameters · 1
Keywords
- Nitrification
- Ammonia
- Electrolysis
- Anode
- Ammonium
- Aeration
Cite
Sanath Kondaveeti, Dae-Hyeon Choi, Md Tabish Noori et al. (2022). Ammonia Removal by Simultaneous Nitrification and Denitrification in a Single Dual-Chamber Microbial Electrolysis Cell. Energies. https://doi.org/10.3390/en15239171
- Journal
- Energies
Open in lab for full controls, parameter editing, and template overlays.
Open in lab