Paper
Bioelectrochemical detection of viable but non-culturable bacterial cells on screen-printed carbon electrodes.
Summary
What the paper reports, in its own words.
Abstract
Bacterial cells in a viable but non-culturable (VBNC) state are metabolically active, but cannot be cultivated using a routine growth medium, which poses a challenge to identifying VBNC contamination in food and the health sector. Non-growth assays for VBNC identification based on membrane integrity and metabolic monitoring are either costly or lead to ambiguous results. Nucleic acid (DNA and RNA) amplification techniques are effective, but their higher cost and complexity prevent routine applications. Bioelectrochemical assays might be a viable alternative for VBNC detection, due to their low cost and rapid analysis time. However, conventional bioelectrochemical methods, in which electrodes are polarized at constant electrochemical potential, are not suitable for monitoring planktonic non-growing cells like VBNC. To circumvent this issue, culturable and VBNC Pseudomonas aeruginosa cells were embedded in hydroxyethyl cellulose (HEC) coating and exposed to alternated cathodic and anodic potentials for a short-time. The resulting current output was interpreted in terms of charge/discharge of the bacterial membrane at the polarized electrode, which is a proxy for bacterial viability. P. aeruginosa cells were induced into the VBNC state by either UV-C or NaOCl. In the presence of 5 mM K 3 [Fe(CN) 6 ] and 20 mM glucose, the current output correlates inversely with the VBNC cells concentration. For cells inactivated by heat or 4% paraformaldehyde, the current output was not significantly different from the blank electrode, indicating the ability of the proposed bioelectrochemical method to detect changes in cellular viability before the loss of culturability.
AI summary: matches the abstract (75% confidence) · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 3 extracted values
Select a citation to see the quote, page and confidence behind a value.
0 of 3 extracted rows modelable
- 1 not canonicalised (no canonical slug)
- 2 no SI value
| Parameter | Value | Unit | Confidence | Source | Modelable |
|---|---|---|---|---|---|
| Dominant organism | Pseudomonas | — | 80% | extracted | Excluded: not canonicalised (no canonical slug) |
| Substrate | glucose | — | 70% | extracted | Excluded: no SI value |
| Anode material | screen-printed carbon | — | 50% | extracted | Excluded: no SI value |
Literature priors
Against the literature
The author’s reported value (▼) sits on top of the literature distribution from MESS-Parameters. Values outside the band are flagged as outliers.
Methodology
What was the system and how was it run
Methodology
Methodology
The study used chronoamperometry with screen-printed carbon electrodes and alternated cathodic and anodic potentials to detect VBNC cells.
Biological parameters
| Field | Value |
|---|---|
| dominant species | ["Pseudomonas"] |
Performance metrics
| Field | Value |
|---|---|
| coulombic efficiency | 4 |
Operational parameters
| Field | Value |
|---|---|
| substrate | ["glucose","cellulose"] |
Outcomes
What was measured and what worked
Key takeaways
Coulombic efficiency
electrochemistry4percent
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
50%
Fraction of expected parameters extracted
Data completeness
60%
Overall extraction coverage across fields
AI confidence
75%
Model self-reported confidence
Mean parameter confidence
67%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Source PDF
The paper as published.
No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 1
Parameters · 1
Keywords
- Electrode
- Bacteria
- Anode
- Microbiology
- Membrane
- Viability assay
Cite
Opeyemi Temitope Otemoye, Sadia Nawab, Feifeng Zhong et al. (2026). Bioelectrochemical detection of viable but non-culturable bacterial cells on screen-printed carbon electrodes. Biofilm. https://doi.org/10.1016/j.bioflm.2026.100354