Research

Paper · MEC

Competition of two highly specialized and efficient acetoclastic electroactive bacteria for acetate in biofilm anode of microbial electrolysis cell

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 70%Substrate ·pure compoundWastewater Treatment

Abstract

AbstractMaintaining functional stability of microbial electrolysis cell (MEC) treating wastewater depends on maintaining functional redundancy of efficient electroactive bacteria (EAB) on the anode biofilm. Therefore, investigating whether efficient EAB competing for the same resources (electron donor and acceptor) co-exist at the anode biofilm is key for the successful application of MEC for wastewater treatment. Here, we compare the electrochemical and kinetic properties of two efficient acetoclastic EAB, Geobacter sulfurreducens (GS) and Desulfuromonas acetexigens (DA), grown as monoculture in MECs fed with acetate. Additionally, we monitor the evolution of DA and GS in co-culture MECs fed with acetate or domestic wastewater using fluorescent in situ hybridization. The apparent Monod kinetic parameters reveal that DA possesses higher jmax (10.7 ± 0.4 A/m²) and lower KS, app (2 ± 0.15 mM) compared to GS biofilms (jmax: 9.6 ± 0.2 A/m² and KS, app: 2.9 ± 0.2 mM). Further, more donor electrons are diverted to the anode for respiration in DA compared to GS. In acetate-fed co-culture MECs, DA (98% abundance) outcompete GS for anode-dependent growth. In contrast, both EAB co-exist (DA: 55 ± 2%; GS: 24 ± 1.1%) in wastewater-fed co-culture MECs despite the advantage of DA over GS based on kinetic parameters alone. The co-existence of efficient acetoclastic EAB with high current density in MECs fed with wastewater is significant in the context of functional redundancy to maintain stable performance. Our findings also provide insight to future studies on bioaugmentation of wastewater-fed MECs with efficient EAB to enhance performance.

AI summary: matches the abstract (70% confidence) · review against source PDF

Key findings

  • 4 A/m²) and lower KS, app (2 ± 0.
  • In contrast, both EAB co-exist (DA: 55 ± 2%; GS: 24 ± 1.
  • 1%) in wastewater-fed co-culture MECs despite the advantage of DA over GS based on kinetic parameters alone.
02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 61 extracted values

Select a citation to see the quote, page and confidence behind a value.

31 of 60 extracted rows modelable

  • 1 not canonicalised (no canonical slug)
  • 17 no SI value
  • 1 outside physical bounds
  • 9 not marked applicable to modeling
  • 1 verifier rejected the value
ParameterValueUnitConfidenceSourceNotesModelable
Substrateacetate,wastewater—80%
llm
Coulombic efficiency110Outside physical range, check source%95%
chronoamperometry
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: outside physical bounds
Coulombic efficiency98%95%
chronoamperometry
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Current Density (Areal)9.9A/m²95%
chronoamperometry
"A slight decrease in peak current density was observed by reducing the acetate c…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Current Density (Areal)7.2A/m²95%
chronoamperometry
"A slight decrease in peak current density was observed by reducing the acetate c…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Current Density (Areal)9.4A/m²95%
chronoamperometry
"The T-MECGS-NaAc reactor took longer time (40 h) to produce a peak current of 9.…" · T=30°C, pH(an)=7, substrate=acetate, startupModelable
Half Saturation Constant2.9mM95%
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: no SI value
Current Density (Areal)9.6A/m²95%
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Current Density (Areal)×211A/m²95%
chronoamperometry
"In the 1st batch of operation, a peak current density of 11 ± 0.2 A/m2 was obser…" · T=30°C, pH(an)=7, substrate=acetate, startupModelable
Current Density (Areal)10.6A/m²95%
chronoamperometry
"The T-MECGS-NaAc reactor took longer time (40 h) to produce a peak current of 9.…" · T=30°C, pH(an)=7, substrate=acetate, startupModelable
Current Density (Areal)10.7A/m²95%
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Half Saturation Constant2mM95%
chronoamperometry at varying acetate concentrations
"Results suggested that both cultures exhibited a Monod-like saturation curve (Fi…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: no SI value
Current Density (Areal)8A/m²95%
chronoamperometry
"In the 1st batch of operation, a peak current density of 11 ± 0.2 A/m2 was obser…" · T=30°C, pH(an)=7, substrate=acetate, startupModelable
Coulombic efficiency98%95%
extracted
"High CE was observed for both MECDA-NaAc (98 ± 2%) and MECGS-NaAc (>110 ± 10%) f…" · pH(an)=7, substrate=acetate, batchModelable
Biofilm Coverage98%90%
fish-clsm
"The high relative abundance (~98%) of D. acetexigens suggests that current gener…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Current Density (Areal)5A/m²90%
chronoamperometry
"However, the peak current generation (5 ± 0.9 A/m2) in MECco-culture-WW-N2 (Fig.…" · T=30°C, pH(an)=7, substrate=domestic_wastewater_with_glucose, steady_stateModelable
Coulombic efficiency90%90%
chronoamperometry
"The profile of current generation in the reactors fed with synthetic medium did …" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Cathodic Current Efficiency93%90%
gas chromatography
"It should be noted that the cathodic CE (CCE) for H2 measured at the end of a ba…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateModelable
Coulombic efficiency39%90%
chronoamperometry
"When domestic wastewater was used as the main source of carbon and energy, the c…" · T=30°C, pH(an)=7, substrate=domestic_wastewater_with_glucose, steady_stateModelable
Chemical Oxygen Demand (COD) Removal0.065h⁻¹90%
hplc
"In both reactors, the acetate removal rate followed first-order kinetics with re…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: no SI value
Chemical Oxygen Demand (COD) Removal0.076h⁻¹90%
hplc
"In both reactors, the acetate removal rate followed first-order kinetics with re…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: no SI value
Applied Potential-0.37V vs. Ag/AgCl90%
cyclic voltammetry
"The EKA (the anode potential giving one-half jmax) for D. acetexigens biofilm an…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: not marked applicable to modeling
Applied Potential-0.38V vs. Ag/AgCl90%
cyclic voltammetry
"The EKA (the anode potential giving one-half jmax) for D. acetexigens biofilm an…" · T=30°C, pH(an)=7, substrate=acetate, steady_stateExcluded: not marked applicable to modeling
Biofilm Coverage44%90%
fish-clsm
"As observed in the MEC reactors fed with acetate, the relative abundance of D. a…" · T=30°C, pH(an)=7, substrate=domestic_wastewater_with_glucose, steady_stateModelable
Specific Growth Rate27.9d⁻¹90%
chronoamperometry
"27.9 ± 4.8 d−1 (doubling time of 0.6 ± 0.1 h), 0.051 ± 0.001 g VSS per g COD and…" · T=30°C, pH(an)=7, substrate=acetate, startupModelable
Showing 25 of 60

Methodology

What was the system and how was it run

Methodology

Methodology

The study employed a combination of monoculture and co-culture experiments in microbial electrolysis cells (MECs) to compare the electrochemical and kinetic properties of two efficient acetoclastic electroactive bacteria (EAB) and monitor their coexistence.

System configuration

FieldValue
system typeMEC

Biological parameters

FieldValue
microbial communityfor acetate in biofilm anode of microbial electrolysis cell

Performance metrics

FieldValue
citation count39

Operational parameters

FieldValue
substrate["acetate","wastewater"]

Electrochemical data

FieldValue
max current density0.4

Operating conditions

9 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-128572d4cab6c384307—acetate630—startup—-0.1—
v2-52459fd6cf4ecd10307——500—steady_state—-0.1—
v2-64b476fb8837ceb8307—acetate380—steady_state—-0.1—
v2-7bb46dd8c06db06e—7—acetate380—batch———
v2-89fa3cc9e6625dbc307—domestic_wastewater_with_glucose400—steady_state—-0.1—
v2-92d7114005d87ce7307—acetate——steady_state—-0.1—
v2-bc88eb1c9b58fbe6307—domestic_wastewater_with_glucose600—steady_state—-0.1—
v2-c8658e321c5e20d0307—acetate——startup—-0.1—
v2-cfddb22cbcea634b307————steady_state—-0.1—

Microbial kinetics

3 constants
OrganismSubstrateParameterValueUnitConf.
Desulfuromonas acetexigensacetateKs2millimolar97%
Geobacter sulfurreducensacetateKs2.9millimolar97%
Geobacter sulfurreducensacetateKs2.9millimolar80%

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

50%

Fraction of expected parameters extracted

Data completeness

60%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

89%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MEC

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

MEC
System
11.0amperes per square metre
Best result · Current density
best of 11
61
Extracted values
2021
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Organisms · 4

Keywords

  • Biofilm
  • Microbial electrolysis cell
  • Anode
  • Competition (biology)
  • Electrolysis
  • Bacteria

Cite

Veerraghavulu Sapireddy, Krishna P. Katuri, Ali Muhammad et al. (2021). Competition of two highly specialized and efficient acetoclastic electroactive bacteria for acetate in biofilm anode of microbial electrolysis cell. npj Biofilms and Microbiomes. https://doi.org/10.1038/s41522-021-00218-3

Open in lab for full controls, parameter editing, and template overlays.

Open in lab