Research

Paper · MFC

Membrane filtration biocathode microbial fuel cell for nitrogen removal and electricity generation

01

Summary

What the paper reports, in its own words.

3D Interactive ModelPower Generation

Abstract

Conductive materials with attached biofilms, were used as membrane filtration biocathodes to filter the effluent and supply electrons for denitrification. Stainless steel mesh and carbon felt were employed to fabricate membrane modules, and the two MFC systems were termed as M1 and M2, respectively. High effluent quality was obtained with M1 and M2 in terms of turbidity, COD and ammonium. In M1, no bioelectrochemical denitrification took place, while nitrate decreased from 35.88±4.15 to 27.33±5.32mg-N/L through the membrane in M2, causing a removal efficiency of 23.3±6.5% with respect to cathodic nitrate. The denitrification ceased without electricity. The maximum power densities of M1 and M2 were 121 and 1253mW/m³, respectively. Micrococcus bacteria and rod-shaped bacteria covered the surface of carbon felt and fewer bacteria were found on stainless steel mesh. According to fluorescence in situ hybridization, the putative bacteria affiliated with Paracoccus genus and Pseudomonas spp. dominated in the interior biofilm on carbon felt for denitrification. Results demonstrate that the carbon felt system can perform bioelectrochemical denitrification to polish the effluent.

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 3 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 3 extracted rows modelable

  • 3 no SI value
ParameterValueUnitConfidenceSourceModelable
Cathode materialbiocathode—60%
extracted
Excluded: no SI value
Cathode materialcarbon felt and stainless steel mesh—50%
extracted
Excluded: no SI value
Membrane materialmembrane filtration biocathode—50%
extracted
Excluded: no SI value

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

25%

Fraction of expected parameters extracted

Data completeness

40%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

53%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
3
Extracted values
2014
Year

Keywords

  • Denitrification
  • Effluent
  • Microbial fuel cell
  • Nitrate
  • Filtration (mathematics)
  • Carbon fibers

Cite

Guangyi Zhang, Hanmin Zhang, Yanjie Ma et al. (2014). Membrane filtration biocathode microbial fuel cell for nitrogen removal and electricity generation. Enzyme and Microbial Technology. https://doi.org/10.1016/j.enzmictec.2014.04.005

PubMed
24835100

Open in lab for full controls, parameter editing, and template overlays.

Open in lab