Research

Paper · MFC

Influence of nitrogen limitation on performance of a microbial fuel cell

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 70%Wastewater Treatment

Abstract

We describe the operation of a microbial fuel cell (MFC) system operating on a synthetic wastewater (acetic acid), under conditions of increasing nitrogen limitation. Two MFCs were operated under feed conditions which spanned a range of TKN/COD values of 1.6–28 mg/g. Stable operation was observed in all cases, even when no ammoniacal nitrogen was added to the cell. Improved electrochemical performance (measured as power density, W/m2) was observed as nitrogen limitation was imposed on the cells. Even with no ammonium addition, continuous function of the cell was maintained, at levels consistent with operation at balanced nutrient supplementation. The work has implicated biological nitrogen fixation as a potential source of nitrogen within the MFC. Whilst this hypothesis has yet to be confirmed, the work highlights the opportunity for continuous operation of microbial fuel cells utilising wastewaters with extremely low nitrogen levels, present in pulp and paper, pharmaceutical and petrochemical industries. Further, the described increases in some of the electrochemical indices (e.g. power density) under application of nitrogen limitation may provide a new approach to increasing fuel cell performance. Finally, the lack of any need to add supplemental nitrogen to a MFC-based wastewater treatment technology holds potential for significant financial and environmental savings.

AI summary: matches the abstract (70% confidence) · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 1 extracted value

Select a citation to see the quote, page and confidence behind a value.

ParameterValueUnitConfidenceSource
Substratewastewater—80%
llm

Methodology

What was the system and how was it run

Methodology

Methodology

Two MFCs were operated under feed conditions spanning a range of TKN/COD values of 1.6–28 mg/g.

System configuration

FieldValue
system typeMFC

Performance metrics

FieldValue
citation count10

Operational parameters

FieldValue
substrate["wastewater"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

25%

Fraction of expected parameters extracted

Data completeness

50%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

80%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
1
Extracted values
2011
Year

Keywords

  • Microbial fuel cell
  • Kjeldahl method
  • Nitrogen
  • Effluent
  • Wastewater
  • Pulp and paper industry

Cite

P. Belleville, P. J. Strong, P. H. Dare et al. (2011). Influence of nitrogen limitation on performance of a microbial fuel cell. Water Science and Technology. https://doi.org/10.2166/wst.2011.111

Open in lab for full controls, parameter editing, and template overlays.

Open in lab