Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst
Summary
What the paper reports, in its own words.
Abstract
Abstract Mixed transition metal (Ni & Cu) oxides supported on graphene (NiO-CuO/G) electrocatalyst was fabricated and tested as an efficient and cost-effective cathode for oxygen reduction reaction (ORR) in microbial fuel cells (MFCs). The electrocatalytic activity and selectivity of the NiO-CuO/G for ORR were examined using linear sweep voltammetry measurements (LSV) on a rotating disc electrode (RDE) in pH-neutral electrolyte. In comparison with a benchmark platinum cathode, the NiO-CuO/G showed high selectivity towards the ORR. The analysis of Koutecky-Levich relationship suggests that the electrocatalyst follows the four-electron ORR pathway. NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density 21.25 mWm − 2 compared to 50.4 mW m − 2 for Pt/C. Both scanning and transmission electron microscope analyses of anodic biofilm showed that a thick biofilm was successfully developed with a rod-like shape. Biochemical characterization of the communities showed that four genera named Escherichia coli ( E-coli ), Shewanella putrefaciens , Bacillus cereus and Bacillus Thuringiensis/mycoides , which belonging to GammaProteobacteria and Firmicutesphyla thatwerethe most abundant bacteria in the anodic biofilm. Our results revealed that NiO-CuO/G cathode demonstrates an enhanced electrocatalytic activity toward ORR in a pH-neutral solution; thus, the newly developed mixed transition metal oxides electrocatalyst can replace other expensive Pt-based catalysts for MFC application.
AI summary: matches the abstract (70% confidence) · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 47 extracted values
Select a citation to see the quote, page and confidence behind a value.
30 of 47 extracted rows modelable
- 4 not canonicalised (no canonical slug)
- 9 no SI value
- 4 verifier rejected the value
| Parameter | Value | Unit | Confidence | Source | Notes | Modelable |
|---|---|---|---|---|---|---|
| Electrode Surface Area | 0.196 | cm² | 95% | geometric measurement | "The working electrode (with a geometrical surface area 0.196 cm2) was either NiO…" · condition_hint=RDE electrode design parameter, electrode_material=glassy carbon disk | Modelable |
| Reactor Volume | 100 | ml | 95% | geometric measurement | "All MFCs experiments were conducted using single-chamber, air-cathode MFCs (6 cm…" · condition_hint=MFC design parameter | Modelable |
| Electrode Spacing | 5 | cm | 95% | geometric measurement | "They were positioned in the other side of the chamber (perpendicularly to the ca…" · condition_hint=MFC design parameter | Modelable |
| Substrate Concentration | 50 | mM | 95% | gravimetric preparation | "The cyclic voltammogram (CV) experiments were conducted in 50mM phosphate buffer…" · T=25°C, pH(an)=7.2 | Excluded: no SI value |
| Catalyst Loading | 0.3 | mg/cm² | 95% | gravimetric measurement | "The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode design parameter, electrode_material=carbon cloth cathode | Excluded: no SI value |
| Substrate Concentration | 1,470 | mg/L | 95% | gravimetric calculation | "MFCs were fed with artificial wastewater containing: sodium acetate (2gL-1) as t…" · T=25°C, pH(an)=7.2, substrate=acetate | Modelable |
| Electrode Surface Area | 18.5 | cm² | 95% | geometric measurement | "They had an effective dimension of 2.5 x 2.5 x 0.6 cm and the projected surface …" · condition_hint=anode electrode design parameter, electrode_material=carbon felt | Modelable |
| Electrode Surface Area | 16.6 | cm² | 95% | geometric measurement | "The gas-diffusion carbon cloth electrodes were used as cathode electrode (6 x 6 …" · condition_hint=cathode electrode design parameter, electrode_material=carbon cloth | Modelable |
| Power Density (Basis Unresolved) | 21.3 | mWm⁻² | 95% | extracted | "NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=sodium acetate, fed_batch | Excluded: no SI value |
| Chemical Oxygen Demand (COD) Removal | 92 | % | 90% | cod assay | "In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Open Circuit Voltage | 654 | mV | 90% | open-circuit voltage measurement | "After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Voltage | 720 | mV | 90% | polarization curve | "The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Internal Resistance | 12,000 | Ω | 90% | polarization curve linear regression | "The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Coulombic efficiency | 25 | % | 90% | coulombic efficiency calculation | "Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Internal Resistance | 9,470 | Ω | 90% | polarization curve linear regression | "The internal resistance of NiO-CuO/G (11955 Ω) is slightly higher than the Pt/C …" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Coulombic efficiency | 35 | % | 90% | coulombic efficiency calculation | "Pt/C shows significantly higher Coulombic efficiency (CE) (35 ± 0.69%) than NiO-…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Voltage | 541 | mV | 90% | polarization curve | "The maximum voltage output of NiO-CuO/G-based MFC is slightly lower than that of…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Open Circuit Voltage | 835 | mV | 90% | open-circuit voltage measurement | "After 62 days of operation, MFCs exhibited a stable OCV of 835mV for Pt/C-based …" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Onset Potential | 400 | mV | 90% | linear sweep voltammetry | "Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2 | Excluded: no SI value |
| Onset Potential | 163 | mV | 90% | linear sweep voltammetry | "Although the onset potential of Pt/C has a more positive onset potential (400 mV…" · T=25°C, pH(an)=7.2 | Excluded: no SI value |
| Electron Recovery Efficiency | 4 | — | 90% | koutecky-levich equation | "It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2 | Modelable |
| Chemical Oxygen Demand (COD) Removal | 93 | % | 90% | cod assay | "In the case of NiO-CuO/G-based MFC, the COD removal percentage (92 ± 1.1%) was s…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Electron Recovery Efficiency | 3.94 | — | 90% | koutecky-levich equation | "It is calculated from to be 3.94 at -0.1 V and 4 at − 0.4 V in case of Pt/C" · T=25°C, pH(an)=7.2 | Modelable |
| Power Density Areal | 21.3 | mW/m² | 85% | polarization curve | "NiO-CuO/G cathode in an air-cathode MFC exhibited a slightly lower power density…" · T=25°C, pH(an)=7.2, substrate=acetate, steady_state | Modelable |
| Electron Recovery Efficiency | 3.56 | — | 85% | koutecky-levich equation | "while it is about ~ 4 at -0.1 V and 3.56 at − 0.4V for NiO-CuO/G" · T=25°C, pH(an)=7.2 | Modelable |
Methodology
What was the system and how was it run
Methodology
Methodology
The study used linear sweep voltammetry measurements and scanning and transmission electron microscopy to analyze the electrocatalytic activity and selectivity of the NiO-CuO/G electrocatalyst.
System configuration
| Field | Value |
|---|---|
| chamber configuration | air-cathode |
| system type | MFC |
Electrode specifications
| Field | Value |
|---|---|
| materials | ["graphene","platinum","copper","nickel"] |
Biological parameters
| Field | Value |
|---|---|
| microbial community | </italic> and <italic>firmicutesphyla</italic>thatwerethe most abundant bacteria in the anodic biofilm |
Operating conditions
9 runs extracted| Run | T°C | pHan | pHcat | Substrate | [S]mg/L | HRTh | Mode | R_extΩ | V_appV | Inoculum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-07f45d82675bae2a | 25 | 7.2 | — | — | — | — | — | — | -0.4 | — |
| v2-0aae13cf23c31a02 | 25 | 7.2 | — | — | — | — | — | — | -0.1 | — |
| v2-0ba7c96606152ee4 | 25 | 7.2 | — | — | — | — | — | — | -0.6 | — |
| v2-18e0dd258c3f7bd6 | 25 | 7.2 | — | acetate | 2000 | — | steady_state | 1000 | — | — |
| v2-25d3f85871ac2ebb | 25 | 7.2 | — | sodium acetate | 2000 | — | fed_batch | — | — | — |
| v2-43ec39334e9263ec | 25 | 7.2 | — | acetate | 2000 | — | steady_state | — | — | — |
| v2-446a181dd772387a | 25 | 7.2 | — | — | — | — | — | — | — | — |
| v2-d06a1c96eea6cd40 | 25 | 7.2 | — | acetate | 2000 | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
38%
Fraction of expected parameters extracted
Data completeness
40%
Overall extraction coverage across fields
AI confidence
70%
Model self-reported confidence
Mean parameter confidence
85%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Source PDF
The paper as published.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 1
Keywords
- Electrocatalyst
- Linear sweep voltammetry
- Microbial fuel cell
- Non-blocking I/O
- Cyclic voltammetry
- Cathode
Cite
Dena Z Khater, Rabab S Amin, Monera O Zhran et al. (2021). Enhancement of microbial fuel cell performance by anodic communities adaptation and cathodic mixed nickel copper oxides (NiO-CuO) on graphene electrocatalyst. Research Square. https://doi.org/10.21203/rs.3.rs-405277/v1
- Journal
- Research Square
Open in lab for full controls, parameter editing, and template overlays.
Open in lab