Research

Paper · MFC

Evaluation of microbial fuel cell coupled with aeration chamber and bio-cathode for organic matter and nitrogen removal from synthetic domestic wastewater

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 70%Wastewater Treatment

Abstract

For simultaneous carbon and nitrogen removal via single stream, a microbial fuel cell (MFC) coupled with an aeration chamber and a bio-cathode was investigated. Without catalysts and any additional buffer, the MFC produced electricity continuously and the power density reached 1.3 W/m³ at a loading rate of 1.6 kg COD/m³ d. Simultaneously, the COD and the nitrate removal rate were 1.4 kg COD/m³ d and 67 g NO3-N/m³ d, respectively. When the hydraulic retention time was changed from 6 to 0.75 hours, the power density significantly increased from 0.2 to 10.8 W/m³ due to an increase of cathodic potential. When the aeration chamber was removed and the nitrate was injected into the cathode, the power density increased to 3.7 W/m³. At a high recirculation rate of 10 ml/min, the power density and the nitrate removal rate greatly increased to 34 W/m³ and 294 g NO3−-N/m3 d, respectively.

AI summary: matches the abstract (70% confidence) · review against source PDF

Key findings

  • [object Object]
  • [object Object]
  • [object Object]
02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 6 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 5 extracted rows modelable

  • 1 not canonicalised (no canonical slug)
  • 4 no SI value
ParameterValueUnitConfidenceSourceModelable
Substratewastewater—80%
llm
Cathode materialfor organic matter and nitrogen removal from synthetic domestic wastewater—70%
extracted
Excluded: no SI value
Catalysts and any additional buffer—60%
extracted
Excluded: not canonicalised (no canonical slug)
Volume10mL60%
extracted
Excluded: no SI value
Hydraulic retention time0.75h50%
extracted
Excluded: no SI value
Cathode materialbio-cathode—50%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

A microbial fuel cell (MFC) coupled with an aeration chamber and bio-cathode was investigated for simultaneous carbon and nitrogen removal from synthetic domestic wastewater.

System configuration

FieldValue
system typeMFC

Performance metrics

FieldValue
citation count16

Operational parameters

FieldValue
substrate["wastewater"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

38%

Fraction of expected parameters extracted

Data completeness

60%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

62%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
6
Extracted values
2009
Year

Keywords

  • Microbial fuel cell
  • Aeration
  • Wastewater
  • Organic matter
  • Waste management
  • Nitrogen

Cite

J. Cha, C. Kim, S. Choi et al. (2009). Evaluation of microbial fuel cell coupled with aeration chamber and bio-cathode for organic matter and nitrogen removal from synthetic domestic wastewater. Water Science and Technology. https://doi.org/10.2166/wst.2009.489

Open in lab for full controls, parameter editing, and template overlays.

Open in lab