Research

Paper · MFC

Effects of temporary external voltage on the performance and community of microbial fuel cells

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 70%Wastewater Treatment

Abstract

Abstract This study evaluated the effects of temporary external voltage on the performance of two-chambered microbial fuel cells (MFC) that use nitrate wastewater as a substrate. Results indicate that the external voltage affected the performance of the MFC during their operation, and this effect remained even after the voltage was removed. The degradation efficiency of the chemical oxygen demand increased in the MFC under external voltages of 0.5, 0.8, and 1.1 V, and the optimal applied voltage was 1.1 V. Compared with the control group without external voltages, the MFC under a voltage of 1.1 V achieved higher current densities and efficiency of nitrate removal during their operation. The MFC with an applied voltage of 1.1 V also achieved the highest maximum power density of 2,035.08 mW/m³. The applied voltages of 0.5 and 0.8 V exerted a positive effect on the performance of the MFC. High-throughput sequencing was used to explore the anode and cathode biofilms. Results showed that the influence was highly associated with microbial community in bio-anode. The predominant functional family changed from Methanotrichaceae during start-up to Flavobacteriaceae in a steady phase.

AI summary: matches the abstract (70% confidence) · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 6 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 5 extracted rows modelable

  • 3 not canonicalised (no canonical slug)
  • 2 no SI value
ParameterValueUnitConfidenceSourceModelable
Substratewastewater—80%
llm
Chambers2—80%
extracted
Excluded: not canonicalised (no canonical slug)
Reactor typedual-chamber—80%
extracted
Excluded: not canonicalised (no canonical slug)
Anode materialand cathode biofilms—70%
extracted
Excluded: no SI value
Cathode materialbiofilms—70%
extracted
Excluded: no SI value
Microbial communityin bio-anode—50%
extracted
Excluded: not canonicalised (no canonical slug)

Methodology

What was the system and how was it run

Methodology

Methodology

This study used two-chambered MFCs with nitrate wastewater as substrate and evaluated effects of external voltage on performance.

System configuration

FieldValue
chamber configurationtwo
system typeMFC

Biological parameters

FieldValue
dominant speciesfunctional family changed from methanotrichaceae during start-up to flavobacteriaceae in a steady phase
microbial communityin bio-anode

Performance metrics

FieldValue
citation count8

Operational parameters

FieldValue
substrate["wastewater"]

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

50%

Fraction of expected parameters extracted

Data completeness

60%

Overall extraction coverage across fields

AI confidence

70%

Model self-reported confidence

Mean parameter confidence

72%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
6
Extracted values
2020
Year

Keywords

  • Microbial fuel cell
  • Anode
  • Voltage
  • Cathode
  • Nitrate
  • Wastewater

Cite

Jing Guo, Jianping Cheng, Jiaquan Wang et al. (2020). Effects of temporary external voltage on the performance and community of microbial fuel cells. Water Science and Technology. https://doi.org/10.2166/wst.2020.251

Open in lab for full controls, parameter editing, and template overlays.

Open in lab