Research

Paper · MFC

Enhanced nitrogen removal in single‐chamber microbial fuel cells with increased gas diffusion areas

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 60%Power Generation

Abstract

Abstract Single‐chamber microbial fuel cells (MFCs) with nitrifiers pre‐enriched at the air cathodes have previously been demonstrated as a passive strategy for integrating nitrogen removal into current‐generating bioelectrochemical systems. To further define system design parameters for this strategy, we investigated in this study the effects of oxygen diffusion area and COD/N ratio in continuous‐flow reactors. Doubling the gas diffusion area by adding an additional air cathode or a diffusion cloth significantly increased the ammonia and COD removal rates (by up to 115% and 39%), ammonia removal efficiency (by up to 134%), the cell voltage and cathode potentials, and the power densities (by a factor of approximately 2). When the COD/N ratio was lowered from 13 to 3, we found up to 244% higher ammonia removal rate but at least 19% lower ammonia removal efficiency. An increase of COD removal rate by up to 27% was also found when the COD/N ratio was lowered from 11 to 3. The Coulombic efficiency was not affected by the additional air cathode, but decreased by an average of 11% with the addition of a diffusion cloth. Ammonia removal by assimilation was also estimated to understand the ammonia removal mechanism in these systems. These results showed that the doubling of gas diffusion area enhanced N and COD removal rates without compromising electrochemical performance. Biotechnol. Bioeng. 2013; 110: 785–791. © 2012 Wiley Periodicals, Inc.

AI summary: matches the abstract (60% confidence) · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 2 extracted values

Select a citation to see the quote, page and confidence behind a value.

0 of 2 extracted rows modelable

  • 2 no SI value
ParameterValueUnitConfidenceSourceModelable
Cathode materialair-cathode—60%
extracted
Excluded: no SI value
Cathode materialair cathode—50%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

The study used continuous-flow reactors with nitrifiers pre-enriched at the air cathodes to investigate the effects of oxygen diffusion area and COD/N ratio on nitrogen removal.

Electrode specifications

FieldValue
cathode materialair cathode

Performance metrics

FieldValue
citation count29

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

38%

Fraction of expected parameters extracted

Data completeness

50%

Overall extraction coverage across fields

AI confidence

60%

Model self-reported confidence

Mean parameter confidence

55%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
2
Extracted values
2012
Year

Keywords

  • Microbial fuel cell
  • Ammonia
  • Cathode
  • Diffusion
  • Faraday efficiency
  • Nitrogen

Cite

Hengjing Yan, John M. Regan (2012). Enhanced nitrogen removal in single‐chamber microbial fuel cells with increased gas diffusion areas. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.24769

Open in lab for full controls, parameter editing, and template overlays.

Open in lab