Paper · MFC
Enhanced nitrogen removal in single‐chamber microbial fuel cells with increased gas diffusion areas
Summary
What the paper reports, in its own words.
Abstract
Abstract Single‐chamber microbial fuel cells (MFCs) with nitrifiers pre‐enriched at the air cathodes have previously been demonstrated as a passive strategy for integrating nitrogen removal into current‐generating bioelectrochemical systems. To further define system design parameters for this strategy, we investigated in this study the effects of oxygen diffusion area and COD/N ratio in continuous‐flow reactors. Doubling the gas diffusion area by adding an additional air cathode or a diffusion cloth significantly increased the ammonia and COD removal rates (by up to 115% and 39%), ammonia removal efficiency (by up to 134%), the cell voltage and cathode potentials, and the power densities (by a factor of approximately 2). When the COD/N ratio was lowered from 13 to 3, we found up to 244% higher ammonia removal rate but at least 19% lower ammonia removal efficiency. An increase of COD removal rate by up to 27% was also found when the COD/N ratio was lowered from 11 to 3. The Coulombic efficiency was not affected by the additional air cathode, but decreased by an average of 11% with the addition of a diffusion cloth. Ammonia removal by assimilation was also estimated to understand the ammonia removal mechanism in these systems. These results showed that the doubling of gas diffusion area enhanced N and COD removal rates without compromising electrochemical performance. Biotechnol. Bioeng. 2013; 110: 785–791. © 2012 Wiley Periodicals, Inc.
AI summary: matches the abstract (60% confidence) · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 2 extracted values
Select a citation to see the quote, page and confidence behind a value.
0 of 2 extracted rows modelable
- 2 no SI value
| Parameter | Value | Unit | Confidence | Source | Modelable |
|---|---|---|---|---|---|
| Cathode material | air-cathode | — | 60% | extracted | Excluded: no SI value |
| Cathode material | air cathode | — | 50% | extracted | Excluded: no SI value |
Methodology
What was the system and how was it run
Methodology
Methodology
The study used continuous-flow reactors with nitrifiers pre-enriched at the air cathodes to investigate the effects of oxygen diffusion area and COD/N ratio on nitrogen removal.
Electrode specifications
| Field | Value |
|---|---|
| cathode material | air cathode |
Performance metrics
| Field | Value |
|---|---|
| citation count | 29 |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
38%
Fraction of expected parameters extracted
Data completeness
50%
Overall extraction coverage across fields
AI confidence
60%
Model self-reported confidence
Mean parameter confidence
55%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
Keywords
- Microbial fuel cell
- Ammonia
- Cathode
- Diffusion
- Faraday efficiency
- Nitrogen
Cite
Hengjing Yan, John M. Regan (2012). Enhanced nitrogen removal in single‐chamber microbial fuel cells with increased gas diffusion areas. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.24769
Open in lab for full controls, parameter editing, and template overlays.
Open in lab