Microfluidic Bioelectrochemical Cell Platform for the Study of Extracellular Electron Uptake in Microbes
Summary
What the paper reports, in its own words.
Abstract
Miniaturization of measurement systems offers several advantages, including reduced sample and reagent volumes, improved control over experimental conditions, and the ability to multiplex complementary measurement modalities, thereby enabling new types of studies in microbial electrochemistry. We present a scalable glass-based microfluidic bioelectrochemical cell (µ-BEC) platform for multiplexed investigations of microbial extracellular electron uptake (EEU). The platform integrates eight independently addressable three-electrode cells in a 2×4 array, with transparent working electrodes that support simultaneous electrochemical analysis and optical imaging. Using Rhodopseudomonas palustris TIE-1 as a model phototroph, we measured EEU activity under light-dark cycling. Microfluidic flow was used to selectively remove planktonic cells, enabling isolation of the electron uptake signal associated with surface attached cells. These results demonstrate the µ-BEC as a robust and adaptable platform for probing microbial electron transfer, with broad potential for high-throughput and multimodal studies.
AI summary
90% confidenceInternational BES research in biotechnology with focus on biotechnology, electrode. Miniaturization of measurement systems offers several advantages, including reduced sample and reagent volumes, ...
Generated by MESSAI extraction pipeline · review against source PDF
Extracted values
Every value pulled from the paper, with its source, so each number can be checked against the text.
n = 43 extracted values
Select a citation to see the quote, page and confidence behind a value.
14 of 43 extracted rows modelable
- 19 not canonicalised (no canonical slug)
- 3 no SI value
- 7 not marked applicable to modeling
| Parameter | Value | Unit | Confidence | Source | Notes | Modelable |
|---|---|---|---|---|---|---|
| Microfluidic well diameter | 4 | mm | 95% | device design specification | "These electrodes are enclosed within 4-mm diameter, 100-µm deep wells isotropica…" | Excluded: not canonicalised (no canonical slug) |
| Channel Width | 500 | µm | 95% | device design specification | "To enable efficient removal of planktonic cells during microbial experiments, ea…" | Modelable |
| Electrode Surface Area | 1.96 | mm² | 95% | device design specification | "The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=indium tin oxide (ITO) | Modelable |
| Electrode Surface Area | 5.93 | mm² | 95% | device design specification | "The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=gold | Modelable |
| Channel Depth | 100 | µm | 95% | device design specification | "These electrodes are enclosed within 4-mm diameter, 100-µm deep wells isotropica…" | Modelable |
| Pseudoreference electrode exposed surface area | 1.29 | mm² | 95% | device design specification | "The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=silver | Excluded: not canonicalised (no canonical slug) |
| Pseudoreference electrode net potential change | -36 | mV | 90% | open circuit potential measurement | "corresponding to a net potential change of –36 mV over the 120-hour testing peri…" · substrate=freshwater_media | Excluded: not canonicalised (no canonical slug) |
| Pseudoreference electrode potential drift | -0.3 | mV h⁻¹ | 90% | open circuit potential measurement | "The pseudoreference electrodes exhibited an average potential drift of –0.30 mV …" · substrate=freshwater_media | Excluded: not canonicalised (no canonical slug) |
| Standard Potential | 174 | mV | 90% | cyclic voltammetry calibration | "microfabricated Ag/AgCl/NafionTM pseudoreference electrodes displayed an average…" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Standard Potential | 214 | mV | 90% | cyclic voltammetry calibration | "Commercial Ag/AgCl/3 M KCl reference electrodes exhibited an average half-wave p…" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Pseudoreference electrode initial potential | 167 | mV | 90% | open circuit potential measurement | "The electrodes began at an average potential of 167 mV (standard deviation: 4.54…" · substrate=freshwater_media | Excluded: not canonicalised (no canonical slug) |
| Pseudoreference electrode potential offset versus Ag/AgCl/3 M KCl | -40 | mV | 90% | cyclic voltammetry calibration | "corresponding to an average potential offset of –40 mV versus Ag/AgCl/3 M KCl" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Pseudoreference electrode final potential | 131 | mV | 90% | open circuit potential measurement | "and concluded at 131 mV (standard deviation: 8.82 mV, CV: 6.7%), corresponding t…" · substrate=freshwater_media | Excluded: not canonicalised (no canonical slug) |
| Cathode Potential | 176 | mV | 85% | cyclic voltammetry | "Scan Rate: 20 mV/s, Cathodic Peak Potential [mV] Average: 176" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Cathode Potential | 182 | mV | 85% | cyclic voltammetry | "Scan Rate: 5 mV/s, Cathodic Peak Potential [mV] Average: 182" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Cathode Potential | 177 | mV | 85% | cyclic voltammetry | "Scan Rate: 15 mV/s, Cathodic Peak Potential [mV] Average: 177" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Cathode Potential | 176 | mV | 85% | cyclic voltammetry | "Scan Rate: 25 mV/s, Cathodic Peak Potential [mV] Average: 176" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
| Anodic peak potential at 20 mV/s | 252 | mV | 85% | cyclic voltammetry | "Scan Rate: 20 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Anodic peak potential at 15 mV/s | 254 | mV | 85% | cyclic voltammetry | "Scan Rate: 15 mV/s, Anodic Peak Potential [mV] Average: 254" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Cathodic R-squared value | 1 | — | 85% | randles-ševčík analysis | "Anodic and cathodic peak currents exhibited a linear relationship with the squar…" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Anodic peak potential at 25 mV/s | 252 | mV | 85% | cyclic voltammetry | "Scan Rate: 25 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Anodic R-squared value | 0.999 | — | 85% | randles-ševčík analysis | "Anodic and cathodic peak currents exhibited a linear relationship with the squar…" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Anodic peak potential at 10 mV/s | 254 | mV | 85% | cyclic voltammetry | "Scan Rate: 10 mV/s, Anodic Peak Potential [mV] Average: 254" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Anodic peak potential at 5 mV/s | 252 | mV | 85% | cyclic voltammetry | "Scan Rate: 5 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not canonicalised (no canonical slug) |
| Cathode Potential | 178 | mV | 85% | cyclic voltammetry | "Scan Rate: 10 mV/s, Cathodic Peak Potential [mV] Average: 178" · substrate=ferri_ferrocyanide_in_kcl | Excluded: not marked applicable to modeling |
Methodology
What was the system and how was it run
Methodology
Methodology
A scalable glass-based microfluidic bioelectrochemical cell (µ-BEC) platform was developed to study microbial extracellular electron uptake (EEU) by integrating eight independently addressable three-electrode cells in a 2×4 array.
Biological parameters
| Field | Value |
|---|---|
| dominant species | ["Rhodopseudomonas"] |
Operating conditions
6 runs extracted| Run | T°C | pHan | pHcat | Substrate | [S]mg/L | HRTh | Mode | R_extΩ | V_appV | Inoculum |
|---|---|---|---|---|---|---|---|---|---|---|
| v2-03e6b022e08bfe46 | 30 | — | — | ferri_ferrocyanide_in_kcl | — | — | — | — | — | — |
| v2-3f895831069b8491 | 30 | — | — | freshwater_medium | — | — | steady_state | — | 0.1 | — |
| v2-6215ab02fda8a19d | 30 | — | — | freshwater_medium | — | — | startup | — | 0.1 | — |
| v2-7abfc6466b5a1799 | — | — | — | freshwater_media | — | — | — | — | — | — |
| v2-9824bdc435679478 | — | — | — | ferri_ferrocyanide_in_kcl | — | — | — | — | — | — |
| v2-f586e9af22985397 | — | — | — | — | — | — | — | — | — | — |
Pipeline
Raw extractions, artifacts, quality signal
Extraction quality
honesty signalCalibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.
Parameter completeness
13%
Fraction of expected parameters extracted
Data completeness
30%
Overall extraction coverage across fields
AI confidence
90%
Model self-reported confidence
Mean parameter confidence
86%
Average confidence across PaperParameter rows surfaced above
review against source PDF before citing · scores 0–1
Chart explorer
Move the inputs this paper used and see how the predicted outcome shifts.
Explore model
The reactor in 3D, with flow you can switch on and off.
AI insights
Contradictions, gaps and opportunities found by comparing this paper with the corpus.
Compare similar papers
The nearest papers by system, materials and organisms, with their outcomes side by side.
Source PDF
The paper as published.
Representative model, generic MFC
Tap to interactRepresentative model, generic MFC
Representative MFC — matched on the paper’s system type only, not its reactor or geometry.
In this record
Organisms, parameters and materials this paper reports. Each links to its page.
Organisms · 1
Keywords
- Microfluidics
- Extracellular
- Cell
- Cell biology
- Nanotechnology
- Biophysics
Cite
Andreea Stoica, Karthikeyan Rengasamy, Tahina Onina Ranaivoarisoa et al. (2025). Microfluidic Bioelectrochemical Cell Platform for the Study of Extracellular Electron Uptake in Microbes. Preprints.org. https://doi.org/10.20944/preprints202505.1879.v1