Microfluidic Bioelectrochemical Cell Platform for the Study of Extracellular Electron Uptake in Microbes

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 90%

Abstract

Miniaturization of measurement systems offers several advantages, including reduced sample and reagent volumes, improved control over experimental conditions, and the ability to multiplex complementary measurement modalities, thereby enabling new types of studies in microbial electrochemistry. We present a scalable glass-based microfluidic bioelectrochemical cell (µ-BEC) platform for multiplexed investigations of microbial extracellular electron uptake (EEU). The platform integrates eight independently addressable three-electrode cells in a 2×4 array, with transparent working electrodes that support simultaneous electrochemical analysis and optical imaging. Using Rhodopseudomonas palustris TIE-1 as a model phototroph, we measured EEU activity under light-dark cycling. Microfluidic flow was used to selectively remove planktonic cells, enabling isolation of the electron uptake signal associated with surface attached cells. These results demonstrate the µ-BEC as a robust and adaptable platform for probing microbial electron transfer, with broad potential for high-throughput and multimodal studies.

AI summary

90% confidence

International BES research in biotechnology with focus on biotechnology, electrode. Miniaturization of measurement systems offers several advantages, including reduced sample and reagent volumes, ...

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 43 extracted values

Select a citation to see the quote, page and confidence behind a value.

14 of 43 extracted rows modelable

  • 19 not canonicalised (no canonical slug)
  • 3 no SI value
  • 7 not marked applicable to modeling
ParameterValueUnitConfidenceSourceNotesModelable
Microfluidic well diameter4mm95%
device design specification
"These electrodes are enclosed within 4-mm diameter, 100-µm deep wells isotropica…"Excluded: not canonicalised (no canonical slug)
Channel Width500µm95%
device design specification
"To enable efficient removal of planktonic cells during microbial experiments, ea…"Modelable
Electrode Surface Area1.96mm²95%
device design specification
"The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=indium tin oxide (ITO)Modelable
Electrode Surface Area5.93mm²95%
device design specification
"The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=goldModelable
Channel Depth100µm95%
device design specification
"These electrodes are enclosed within 4-mm diameter, 100-µm deep wells isotropica…"Modelable
Pseudoreference electrode exposed surface area1.29mm²95%
device design specification
"The exposed surface areas of the working, counter, and pseudoreference electrode…" · electrode_material=silverExcluded: not canonicalised (no canonical slug)
Pseudoreference electrode net potential change-36mV90%
open circuit potential measurement
"corresponding to a net potential change of –36 mV over the 120-hour testing peri…" · substrate=freshwater_mediaExcluded: not canonicalised (no canonical slug)
Pseudoreference electrode potential drift-0.3mV h⁻¹90%
open circuit potential measurement
"The pseudoreference electrodes exhibited an average potential drift of –0.30 mV …" · substrate=freshwater_mediaExcluded: not canonicalised (no canonical slug)
Standard Potential174mV90%
cyclic voltammetry calibration
"microfabricated Ag/AgCl/NafionTM pseudoreference electrodes displayed an average…" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Standard Potential214mV90%
cyclic voltammetry calibration
"Commercial Ag/AgCl/3 M KCl reference electrodes exhibited an average half-wave p…" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Pseudoreference electrode initial potential167mV90%
open circuit potential measurement
"The electrodes began at an average potential of 167 mV (standard deviation: 4.54…" · substrate=freshwater_mediaExcluded: not canonicalised (no canonical slug)
Pseudoreference electrode potential offset versus Ag/AgCl/3 M KCl-40mV90%
cyclic voltammetry calibration
"corresponding to an average potential offset of –40 mV versus Ag/AgCl/3 M KCl" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Pseudoreference electrode final potential131mV90%
open circuit potential measurement
"and concluded at 131 mV (standard deviation: 8.82 mV, CV: 6.7%), corresponding t…" · substrate=freshwater_mediaExcluded: not canonicalised (no canonical slug)
Cathode Potential176mV85%
cyclic voltammetry
"Scan Rate: 20 mV/s, Cathodic Peak Potential [mV] Average: 176" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Cathode Potential182mV85%
cyclic voltammetry
"Scan Rate: 5 mV/s, Cathodic Peak Potential [mV] Average: 182" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Cathode Potential177mV85%
cyclic voltammetry
"Scan Rate: 15 mV/s, Cathodic Peak Potential [mV] Average: 177" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Cathode Potential176mV85%
cyclic voltammetry
"Scan Rate: 25 mV/s, Cathodic Peak Potential [mV] Average: 176" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Anodic peak potential at 20 mV/s252mV85%
cyclic voltammetry
"Scan Rate: 20 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Anodic peak potential at 15 mV/s254mV85%
cyclic voltammetry
"Scan Rate: 15 mV/s, Anodic Peak Potential [mV] Average: 254" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Cathodic R-squared value1—85%
randles-ševčík analysis
"Anodic and cathodic peak currents exhibited a linear relationship with the squar…" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Anodic peak potential at 25 mV/s252mV85%
cyclic voltammetry
"Scan Rate: 25 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Anodic R-squared value0.999—85%
randles-ševčík analysis
"Anodic and cathodic peak currents exhibited a linear relationship with the squar…" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Anodic peak potential at 10 mV/s254mV85%
cyclic voltammetry
"Scan Rate: 10 mV/s, Anodic Peak Potential [mV] Average: 254" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Anodic peak potential at 5 mV/s252mV85%
cyclic voltammetry
"Scan Rate: 5 mV/s, Anodic Peak Potential [mV] Average: 252" · substrate=ferri_ferrocyanide_in_kclExcluded: not canonicalised (no canonical slug)
Cathode Potential178mV85%
cyclic voltammetry
"Scan Rate: 10 mV/s, Cathodic Peak Potential [mV] Average: 178" · substrate=ferri_ferrocyanide_in_kclExcluded: not marked applicable to modeling
Showing 25 of 43

Methodology

What was the system and how was it run

Methodology

Methodology

A scalable glass-based microfluidic bioelectrochemical cell (µ-BEC) platform was developed to study microbial extracellular electron uptake (EEU) by integrating eight independently addressable three-electrode cells in a 2×4 array.

Biological parameters

FieldValue
dominant species["Rhodopseudomonas"]

Operating conditions

6 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-03e6b022e08bfe4630——ferri_ferrocyanide_in_kcl——————
v2-3f895831069b849130——freshwater_medium——steady_state—0.1—
v2-6215ab02fda8a19d30——freshwater_medium——startup—0.1—
v2-7abfc6466b5a1799———freshwater_media——————
v2-9824bdc435679478———ferri_ferrocyanide_in_kcl——————
v2-f586e9af22985397——————————

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

13%

Fraction of expected parameters extracted

Data completeness

30%

Overall extraction coverage across fields

AI confidence

90%

Model self-reported confidence

Mean parameter confidence

86%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MFC

Representative MFC — matched on the paper’s system type only, not its reactor or geometry.

MFC
System
43
Extracted values
2025
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Keywords

  • Microfluidics
  • Extracellular
  • Cell
  • Cell biology
  • Nanotechnology
  • Biophysics

Cite

Andreea Stoica, Karthikeyan Rengasamy, Tahina Onina Ranaivoarisoa et al. (2025). Microfluidic Bioelectrochemical Cell Platform for the Study of Extracellular Electron Uptake in Microbes. Preprints.org. https://doi.org/10.20944/preprints202505.1879.v1

Open in lab for full controls, parameter editing, and template overlays.

Open in lab