Research

Paper

Application of humin-immobilized biocathode in a continuous-flow bioelectrochemical system for nitrate removal at low temperature

01

Summary

What the paper reports, in its own words.

AI Enhanced· 90%

AI summary

90% confidence

A continuous-flow bioelectrochemical system using a humin-immobilized biocathode effectively removed nitrate at low temperatures.

Generated by MESSAI extraction pipeline · review against source PDF

Key findings

  • The humin-immobilized biocathode showed improved nitrate removal efficiency compared to a free biocathode.
  • The system maintained stable performance over 30 days of operation at 10°C.
  • The humin-immobilized biocathode also exhibited enhanced tolerance to low temperatures.
02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 1 extracted value

Select a citation to see the quote, page and confidence behind a value.

0 of 1 extracted rows modelable

  • 1 no SI value
ParameterValueUnitConfidenceSourceModelable
Cathode materialbiocathode—60%
extracted
Excluded: no SI value

Methodology

What was the system and how was it run

Methodology

Methodology

The study employed a continuous-flow bioelectrochemical system with a humin-immobilized biocathode and a free biocathode as controls.

Performance metrics

FieldValue
citation count29

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

25%

Fraction of expected parameters extracted

Data completeness

40%

Overall extraction coverage across fields

AI confidence

90%

Model self-reported confidence

Mean parameter confidence

60%

Average confidence across PaperParameter rows surfaced above

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

No 3D model is mapped to this paper yet. The values extracted from it are listed under Extracted values.

1
Extracted values
2021
Year

Keywords

  • Humin
  • Denitrifying bacteria
  • Denitrification
  • Biofilm
  • Nitrate
  • Environmental chemistry

Cite

Dan Chen, Lizhuang Yang, Zhiling Li et al. (2021). Application of humin-immobilized biocathode in a continuous-flow bioelectrochemical system for nitrate removal at low temperature. Environmental Research. https://doi.org/10.1016/j.envres.2021.111677