Applied voltage optimization for denitrification process improvement by denitrifying species of Pseudomonas in microbial electrolysis cell (MEC)

01

Summary

What the paper reports, in its own words.

3D Interactive ModelAI Enhanced· 72%Substrate ·pure compound

Abstract

Denitrification is the conversion process of nitrate to gaseous nitrogen forms carried out by bacteria commonly referred to as denitrifiers. Microbial Electrolysis Cell (MEC) is a type of bioelectrochemical system (BES) that is connected to external power source to aid the reactions. This research investigates the effect of applied voltage value on denitrification by nitrate removal efficiency of two model denitrifying species from the genus Pseudomonas in single-chambered MEC. Pseudomonas aeruginosa and Pseudomonas nitroreducens exhibited native removal efficiency at 70.62% and 68.20%, respectively. These values respectively reached up to 89.67% and 88.58% at 1.20 V, the upper limit of this study. Pseudomonas aeruginosa displayed better performance in MEC based off its produced current stability (mA) across the 0.35-1.20 V range. The effect of applied voltage on nitrate removal efficiency and setup performance was more prominent on known exoelectrogenic species of Pseudomonas such as Pseudomonas aeruginosa compared to Pseudomonas nitroreducens. Operating applied voltages of 0.35 V and 0.70 V was recommended for the application of the system based on technical and economical considerations. Further studies are needed to determine the response of the bacteria on wider range of applied voltages in MEC as well as elucidating these effects on autotrophic systems.

AI summary

72% confidence

This study optimized applied voltage (0.35–1.20 V) in a single-chamber MEC to enhance heterotrophic denitrification by Pseudomonas aeruginosa and P. nitroreducens. Both strains showed voltage-dependent nitrate (NO3−) removal improvement, reaching 89.67% and 88.58% efficiency respectively at 1.20 V, compared to native rates of 70.62% and 68.20%. P. aeruginosa demonstrated superior current stability and voltage sensitivity. However, the authors recommend operating at 0.35–0.70 V for practical deployment despite lower removal efficiency, to maintain advantage over water electrolysis. The study reveals species-specific responses linked to nitrite reductase type (cd1-NIR vs CuNIR) but does not identify the saturation voltage or characterize intermediate nitrogen species.

Key insights

  • Threshold Nitrate removal efficiency increased monotonically with applied voltage from 0.35 V to 1.20 V for both strains (P. aeruginosa: 77.95% → 89.67%; P. nitroreducens: 80.91% → 88.58%), but the maximum improvement point was not reached.

    So what. Operators should test voltages >1.20 V to identify the saturation point and avoid over-applying voltage; current design space is incomplete.

  • Mechanism P. aeruginosa (nirS-type, cd1-NIR) showed maximum nitrate removal activity at later incubation times (after 92 h), while P. nitroreducens (nirK-type, CuNIR) peaked early (68 h), explaining their different kinetic profiles in the 24 h cycle.

    So what. Select denitrifier strain based on HRT: use nirK-type for short residence times, nirS-type for longer anaerobic maturation; do not assume all denitrifiers respond identically to voltage.

  • Performance P. aeruginosa displayed better current stability across 0.35–1.20 V range despite initially lower current at 0.35 V, while P. nitroreducens generated higher absolute current but with less stability, indicating exoelectrogenic activity correlates with voltage robustness, not peak current.

    So what. Prioritize current stability over magnitude when selecting denitrifying strains for MEC; stable current predicts consistent denitrification performance across voltage ranges.

  • Trade-off Operating voltage of 0.35 V and 0.70 V are recommended despite achieving only 77.95–85.36% removal efficiency, because voltages >1.00 V risk bacterial cell membrane damage and lose competitive advantage over water electrolysis (which operates at ~2.00 V).

    So what. Accept a 4–12 percentage-point efficiency loss (vs. 1.20 V) to stay within the safe operating window; do not assume higher voltage always justifies the cost and toxicity risk.

  • Mechanism Biomass accumulation was observed at the anode for both species, with P. nitroreducens showing larger visual accumulation, yet P. aeruginosa maintained superior current stability, suggesting biofilm architecture or mediator secretion (pyocyanin) matters more than biomass quantity.

    So what. Monitor biofilm quality and mediator production, not just anode coverage; pyocyanin-mediated electron transfer may explain P. aeruginosa's stability advantage.

Contradictions1

Tensions the paper itself points to. Each side quotes the passage it comes from.

  • Within the paper P. nitroreducens achieves higher nitrate removal than P. aeruginosa at low voltage (0.35 V) but lower at high voltage (1.20 V), despite P. aeruginosa being described as the more promising species overall.

    One side

    At 0.35 V, P. nitroreducens removal efficiency (80.91%) exceeds P. aeruginosa (77.95%)

    “At lower applied voltage variation (0.35 V) Pseudomonas nitroreducens achieved better nitrate removal efficiency than Pseudomonas aeruginosa.”
    Other side

    P. aeruginosa is concluded as 'the more promising species to be used to treat wastewater via denitrification than Pseudomonas nitroreducens' based on higher sensitivity to voltage and maximum removal at 1.20 V (89.67% vs 88.58%)

    “Based on the attained native nitrate removal efficiency and its improvements in this study, Pseudomonas aeruginosa emerge as the more promising species to be used to treat wastewater via denitrification than Pseudomonas nitroreducens.”

    Authors’ reading. The authors resolve this by prioritizing voltage sensitivity and current stability (P. aeruginosa's strength) over single-point performance at 0.35 V, and by noting that practical operating windows (0.35–0.70 V) are recommended anyway, where the species' relative advantage is less clear. The conclusion emphasizes P. aeruginosa's superior response to voltage increases, not its performance at all voltages.

Opportunity areas6

Specific gaps in this paper, with an experiment that would close each.

  • High No voltage range >1.20 V was tested; the paper explicitly states the saturation point (where further voltage increase yields no improvement) was not identified.

    Text states: 'This study did not find the point at which no further improvement was made over the bacteria's native nitrate removal nor achieved the maximum point.' and 'Further studies are needed to evaluate the response of the bacteria towards higher applied voltage to find the maximum value.'

    Try. Apply 1.40–2.00 V in 0.20 V increments; measure NO3− removal efficiency, current stability, and cell viability (e.g., CFU/mL or membrane integrity assay) to identify toxicity threshold and saturation voltage.

  • High No intermediate nitrogen species (NO2−, N2O, NO, N2) were quantified; only total NO3− removal was tracked, leaving the denitrification pathway and potential N2O emissions uncharacterized.

    The paper emphasizes N2O as a potent greenhouse gas in the introduction but provides no data on N2O accumulation or release. Both strains carry nosZ (N2O reductase), but whether they complete the full pathway to N2 is unknown.

    Try. Measure NO2−, N2O, NO, and N2 via HPLC (NO2−), gas chromatography (N2O, NO, N2), or 15N-labeling across 0.35–1.20 V to map the denitrification pathway and identify any voltage-dependent accumulation of intermediates.

  • Medium No variation in initial NO3− concentration was tested; all experiments used 10 mM NaNO3 (~1,000 ppm NO3−N), which is much higher than typical wastewater (10–100 mg/L NO3−N).

    Text states bacteria 'were able to grow in the medium formulated with high nitrate concentration, close to 1,000 ppm in this study' but does not explore whether the voltage-efficiency relationship holds at environmentally relevant concentrations.

    Try. Repeat voltage optimization at 10, 50, 100, and 500 mg/L NO3−N; measure removal efficiency and current density to determine whether the 0.35–1.20 V window scales to lower substrate concentrations.

  • Medium No variation in C/N ratio or organic carbon source was tested; only acetate + ethanol at fixed 15 mM acetate + 4 mM ethanol was used, and autotrophic denitrification was not explored.

    The paper notes 'Carbon source assessed in this study was limited for heterotrophic bacteria' and recommends future work on autotrophic systems, but provides no data on how voltage optimization performs under carbon limitation or autotrophic conditions.

    Try. Test C/N ratios of 0.5, 1.0, 2.0, and 5.0 (by varying acetate while holding NO3− at 10 mM) at 0.70 V; separately, run autotrophic denitrification with H2 or formate as electron donor and measure removal efficiency and current density.

  • Medium No measurement of pH, dissolved oxygen, or redox potential (Eh) was recorded during the 24 h cycle, despite these being critical drivers of denitrification kinetics and enzyme activity.

    The paper uses methylene blue as a redox indicator for anaerobic confirmation but does not quantify Eh, pH, or DO over time. Cathode pH in particular can shift dramatically under applied voltage and affect denitrification.

    Try. Log pH, DO, and Eh at 0, 4, 8, 12, 24 h across 0.35, 0.70, 1.20 V; correlate these with NO3− removal rate and current density to identify rate-limiting conditions.

  • Low No comparison of single-chamber vs. multi-chamber MEC designs; this study used only a single-chamber configuration, limiting generalizability to compartmentalized systems.

    The paper cites Zhu et al. [13] on three-chambered MEC for autotrophic denitrification but does not test whether the voltage-efficiency relationship differs in separated anode/cathode compartments.

    Try. Replicate the 0.35, 0.70, 1.20 V conditions in a two- or three-chamber MEC with anion exchange membrane separation; measure NO3− removal, current, and pH drift to assess whether compartmentalization changes the optimal voltage window.

Generated by MESSAI extraction pipeline · review against source PDF

02

Extracted values

Every value pulled from the paper, with its source, so each number can be checked against the text.

n = 59 extracted values

Select a citation to see the quote, page and confidence behind a value.

26 of 55 extracted rows modelable

  • 23 not canonicalised (no canonical slug)
  • 3 no SI value
  • 2 not marked applicable to modeling
  • 1 contradicts other papers
ParameterValueUnitConfidenceSourceNotesModelable
VolumeVolumemL100%
nlp
p.5
Nitrogen Concentration88.6%50%
hybrid
p.6
Reactor Volume13mL50%
hybrid
p.55
Metal Removal Efficiency89.7%50%
hybrid
p.6
Current Monitoring Interval10min95%
digital multimeter
"Electrical measurement was done over the anode-resistor connections using digita…" · condition_hint=measurement protocolModelable
Applied Potential1.2V95%
extracted
"Power supply unit (model P-3005A; SUNSHINE Ltd, Guangzhou, China) was used to de…" · condition_hint=maximum applied voltage tested, applied_potential_v=1.2Excluded: not marked applicable to modeling
Applied Potential0.35V95%
extracted
"Power supply unit (model P-3005A; SUNSHINE Ltd, Guangzhou, China) was used to de…" · condition_hint=minimum applied voltage tested, applied_potential_v=0.35Excluded: not marked applicable to modeling
Light Wavelength240nm95%
uhplc with uv-vis detection
"A UV-Vis detector was used at wavelength 240 nm." · condition_hint=UHPLC analysis methodModelable
Calcium Ion Concentration0.0795g/L95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · condition_hint=medium compositionModelable
Internal Resistance10Ω95%
extracted
"A 10 Ω resistor was attached to each line connecting the power supply to the ano…" · condition_hint=measurement circuit resistor for voltage recording, external_resistance_ohm=10Modelable
Substrate Concentration10mM95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · substrate=nitrateExcluded: no SI value
Substrate Concentration0.02g/L95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · condition_hint=medium compositionModelable
Inoculum Volume10%95%
extracted
"Bacterial inoculations from LB broth to MECs were done at 10% of medium volume." · condition_hint=inoculum preparationExcluded: no SI value
Chamber Volume13mL95%
extracted
"The volume of the medium in each MEC was 13 mL." · condition_hint=MEC reactor design parameterModelable
Magnesium Ion Concentration0.235g/L95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · condition_hint=medium compositionModelable
Nitrogen Removal88.6%95%
uhplc
"Table 2. Nitrate removal efficiency across different voltage values. [showing P.…" · T=30°C, substrate=acetate, steady_stateModelable
Nitrogen Removal89.7%95%
uhplc
"Table 2. Nitrate removal efficiency across different voltage values. [showing P.…" · T=30°C, substrate=acetate, steady_stateModelable
Nitrogen Removal70.6%95%
uhplc
"Native nitrate removal efficiency for these bacteria was largely similar at 68.2…" · T=30°C, substrate=acetate, steady_stateModelable
Nitrogen Removal68.2%95%
uhplc
"Native nitrate removal efficiency for these bacteria was largely similar at 68.2…" · T=30°C, substrate=acetate, steady_stateModelable
Reactor Volume Total15mL95%
extracted
"The total liquid volume in the study approached 15 mL, leaving space for gas acc…" · condition_hint=MEC reactor design parameterModelable
Temperature30°C95%
extracted
"Bacterial isolates were grown on LB broth overnight at 30°C prior to inoculation…" · T=30°CModelable
Substrate Concentration1g/L95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · condition_hint=medium compositionModelable
Substrate Concentration1.3g/L95%
extracted
"Medium composition for MEC operation consisted of (in g/L, except stated) [5]: 2…" · condition_hint=medium compositionModelable
Flow Rate0.3mL/min95%
uhplc
"The flow rate was 0.300 mL/min." · condition_hint=UHPLC analysis methodExcluded: contradicts other papers
Trace Element Solution Volume10mL95%
extracted
"Medium composition (final volume 1 L) was completed with 10 mL of modified trace…" · condition_hint=medium composition per 1 LExcluded: not canonicalised (no canonical slug)
Showing 25 of 59

Methodology

What was the system and how was it run

Methodology

Methodology

A single-chamber MEC (20 mL total, 13 mL medium) was inoculated with P. aeruginosa or P. nitroreducens and operated at applied voltages of 0.35, 0.70, and 1.20 V for 24 h at room temperature under anaerobic conditions. Nitrate concentration was measured via UHPLC at 0, 4, 8, 12, 24 h; current was recorded every 10 min via a 10 Ω external resistor and digital multimeter. Nitrate removal efficiency was calculated as the percentage of initial NO3− (10 mM) removed. The medium contained acetate (15 mM) and ethanol (4 mM) as heterotrophic carbon sources, with phosphate buffer, trace elements, and methylene blue as redox indicator.

System configuration

FieldValue
reactor typeMEC
chamber config1-chamber

Biological parameters

FieldValue
dominant species["Pseudomonas"]

Operating conditions

14 runs extracted
RunT°CpHanpHcatSubstrate[S]mg/LHRThModeR_extΩV_appVInoculum
v2-05f2d5be1fcd2e91————————1.2—
v2-2f1affd72d0147e930—————————
v2-47943c5d0681736e———nitrate——————
v2-6456121f4491bddf30——acetate——————
v2-6887a9aa9c61932430——acetate——steady_state—0.7—
v2-a40d1d4d77d18c5f————————0.35—
v2-acb7ac618cfaebe830——acetate——steady_state—1.2—
v2-aec7af5764f7057730——nitrate——————
v2-b64d4d3dce7c1fa4———ethanol——————
v2-bcbfc41816852e9030——acetate——steady_state—0.35—
v2-f2046436d9f74943———acetate——————
v2-f586e9af22985397——————————
v2-f880d2de1a8769af30——acetate——steady_state—0—
v2-ff5348c538bb29e6———————10——

Pipeline

Raw extractions, artifacts, quality signal

Extraction quality

honesty signal

Calibrate your trust in the extracted content against these signals — they're how the pipeline rated its own output for this paper.

Parameter completeness

63%

Fraction of expected parameters extracted

Data completeness

70%

Overall extraction coverage across fields

AI confidence

72%

Model self-reported confidence

Mean parameter confidence

78%

Average confidence across PaperParameter rows surfaced above

Last extraction:vpipeline-v2FULL_EXTRACTIONcompleted59 parameters surfaced

review against source PDF before citing · scores 0–1

03

Chart explorer

Move the inputs this paper used and see how the predicted outcome shifts.

04

Explore model

The reactor in 3D, with flow you can switch on and off.

05

AI insights

Contradictions, gaps and opportunities found by comparing this paper with the corpus.

06

Compare similar papers

The nearest papers by system, materials and organisms, with their outcomes side by side.

07

Source PDF

The paper as published.

loading 3D model…

Representative model, generic MEC

Representative MEC — matched on the paper’s system type only, not its reactor or geometry.

MEC
System
0.50ohms
Best result · Internal resistance
best of 2
59
Extracted values
2018
Year

In this record

Organisms, parameters and materials this paper reports. Each links to its page.

Keywords

  • Denitrifying bacteria
  • Denitrification
  • Pseudomonas
  • Nitrate
  • Environmental chemistry
  • Pseudomonas aeruginosa

Cite

Putty Ekadewi, M. Hardhi, Putri Anggun Puspitarini et al. (2018). Applied voltage optimization for denitrification process improvement by denitrifying species of Pseudomonas in microbial electrolysis cell (MEC). E3S Web of Conferences. https://doi.org/10.1051/E3SCONF/20186702027

Open in lab for full controls, parameter editing, and template overlays.

Open in lab